Dynamic UV-Vis monitoring of ternary pharmaceutical photodegradation using multivariate curve resolution and predictive modeling.
Daysi Elusaí Millán Ocampo, Susana Silva Martínez
Centro de Investigación en Ingeniería y Ciencias Aplicadas, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001. Col. Chamilpa, Cuernavaca, Morelos, C.P. 62209, Mexico. · Centro de Investigación en Ingeniería y Ciencias Aplicadas, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001. Col. Chamilpa, Cuernavaca, Morelos, C.P. 62209, Mexico. Electronic address: ssilva@uaem.mx.
Key points
From the paper's conclusion- These results exceeded the 0.05 threshold, indicating significant non-linear behavior in the calibration datasets.
Abstract
Ultraviolet (UV) photodegradation of multicomponent pharmaceutical systems generates complex spectral signals due to overlapping absorption bands and transient intermediates, limiting conventional quantitative approaches. To address this challenge, an integrated chemometric strategy was developed to predict concentration profiles in dynamic ternary mixtures of paracetamol (PAR), naproxen sodium (NPX), and diclofenac sodium (DIC) in spiked river water using Ultraviolet-visible (UV-Vis) spectroscopy. UV-Vis spectra from individual photolysis experiments were analyzed by Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) to estimate concentration profiles of the parent pharmaceuticals. These profiles were associated with ternary mixture spectra reconstructed by linear combination of the spectral data obtained from the individual photolysis experiments. The combined spectral data, together with experimentally acquired calibration data, served as input to develop a linear Partial Least Squares (PLS) and non-linear Artificial Neural Network (ANN) models, enabling simultaneous prediction of component concentrations. The degree of nonlinearity in the calibration datasets was first assessed using the Non-Linearity Degree (NLD), yielding values of 0.248, 0.398, and 0.214 for PAR, NPX, and DIC, respectively. These results exceeded the 0.05 threshold, indicating significant non-linear behavior in the calibration datasets. Accordingly, the linear PLS model showed limited predictive performance, particularly for DIC. In contrast, the non-linear ANN model achieved higher predictive accuracy, demonstrating its superior suitability for the dynamically evolving multicomponent systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- "Green spectrophotometric determination of rupatadine, its toxic impurity, and methyl paraben: comparative AI-assisted univariate versus multivariate chemometrics".Scientific reports · 2026
- Selective sustainable spectrophotometric techniques for simultaneous estimation of certain binary and ternary mixtures of anti-infective drugs: application in pharmaceutical formulations and spiked human plasmaFuture Journal of Pharmaceutical Sciences · 2026
- Chemometric and learning-based multivariate models for quantifying a challenging quaternary mixture of bupropion, dextromethorphan, and their related impurities by UV-Vis spectrophotometryBMC Chemistry · 2026
- Quantification of paracetamol and flupirtine maleate in tablet formulation by application of spectral modification and principle component regression techniques using R programming.BMC chemistry · 2026
- Holistically benchmarked optimization-assisted green spectrophotometric-chemometric approach for simultaneous determination of piroxicam and venlafaxine in pharmaceutical formulations and spiked human plasma.BMC chemistry · 2026
- Beyond Beer‐Lambert Linear Regression: Multi‐Layer Modeling for Wide‐Range Concentration Quantification Using Ultraviolet‐visible SpectroscopyAnalytical Science Advances · 2026