Influence of Scanning Path and a Mandibular Scanning Aid on Complete Denture Digitization: A Preliminary In Vitro Study
Akiha Ogawa, Mikio Imai, Yohei Jinno, Takamitsu Kato, Yasunori Ayukawa
Key points
From the paper's conclusion- These preliminary findings support further evaluation of scanning aids, particularly at the mandibular lingual border.
Abstract
Background/Objectives: Digitizing an existing complete denture with an intraoral scanner (IOS) may be influenced by scanning path and prosthesis geometry. This preliminary in vitro study compared occlusal-start and intaglio-start scanning and evaluated a mandibular scanning aid. Methods: One maxillary and one mandibular complete denture were scanned five times per protocol with a TRIOS 4 IOS; extraoral scans served as references. The unmodified dentures were scanned in both directions, and the mandibular denture was rescanned after its posterior lingual borders were connected with grooved utility wax. Precision was assessed using 10 pairwise comparisons from five IOS scans; trueness was assessed using five IOS-to-reference comparisons for the unmodified dentures. Two-group comparisons used Mann–Whitney U tests; mandibular protocols were analyzed using Kruskal–Wallis test followed by Dunn’s test with Bonferroni correction. Results: In the maxillary denture, occlusal-start scanning showed better polished-surface precision than intaglio-start scanning (42.50 ± 10.62 vs. 53.82 ± 26.60 µm; p < 0.001), whereas intaglio-surface precision and overall trueness did not differ. In the unmodified mandibular denture, the starting surface did not significantly affect overall precision. Across the four mandibular protocols, overall precision differed on both surfaces (p < 0.001). The modified protocols showed numerically lower overall errors, with the most consistent regional differences at the lingual border. Trueness of the modified denture was not evaluated. Conclusions: In these specimens, the effects of the starting surface and the scanning aid varied by surface and protocol. These preliminary findings support further evaluation of scanning aids, particularly at the mandibular lingual border.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Scan Path and Operator Experience on the Trueness of Extraoral Complete Denture Digitization with an Intraoral Scanner: An Exploratory In Vitro StudyProsthesis · 2026
- Evaluation of the Influence of Scanning Pattern and Scanning Technology on the Trueness and Precision of the Denture Reference TechniqueJournal of Esthetic and Restorative Dentistry · 2026
- Accuracy of digital impressions captured by an intraoral scanner in a partially edentulous mandible.Journal of dental sciences · 2026
- Accuracy of 12 Intraoral Scanners and Photogrammetric Systems for Full-Arch Edentulous Maxillae: An In Vitro Study.The International journal of periodontics & restorative dentistry · 2026
- Effect of a stackable scanning guide, intraoral scanner type, and operator on the accuracy of maxillary full-arch implant scans: An in vitro studyJournal of Dentistry · 2026
- Application of Digital Techniques for the Observation and Fabrication of Removable Partial Dentures.Case reports in dentistry · 2026