  • The results suggest that structural heterogeneity provides a better explanation for the observed electrochemical behaviour than apparent wettability alone.

Abstract

Understanding the relationship between the structure of electrospun coatings and their electrochemical behaviour is important for designing corrosion-resistant surfaces for biomedical alloys. In this work, electrospun polycaprolactone (PCL) and polycaprolactone–bovine serum albumin (PCL–BSA) coatings were deposited on TiZr alloy substrates to examine how coating morphology affects electrochemical behaviour in simulated body fluid (SBF). The incorporation of BSA produced coatings with a broader fibre diameter distribution and a less uniform fibrous network than pristine PCL coatings. These changes were accompanied by lower polarization resistance, higher corrosion current densities and a more pronounced evolution of the impedance response. The results suggest that structural heterogeneity provides a better explanation for the observed electrochemical behaviour than apparent wettability alone. Fibre morphology and structural heterogeneity should be considered together when designing electrospun coatings for biomedical applications.