Composition-Dependent Electrochemical Behavior and Preliminary Biological Screening of Hydrothermal Hydroxyapatite–Chitosan–Palladium Coatings on β-Ti30Zr5Mo
Oktay Yiğit, Selçuk Karataş, Burak Dikici, Carl J. Boehlert, Jonathan Hardy, Xiaoli Zhao, Mitsuo Niinomi
Key points
From the paper's conclusion- Because compositions were not replicated across independent batches, no uncoated control was tested, and the chitosan formulation also introduced acetic acid and additional NH4OH, the data show co-occurring composition-dependent changes in chemistry, morphology and electrochemical response rather than a demonstrated mechanism.
Abstract
Multifunctional hydroxyapatite (HA) coatings often combine a barrier-forming organic component with an antimicrobial metal, but these functions need not remain additive. HA, HA–1Pd, HA–2Pd, HA–Cs, HA–Cs–1Pd and HA–Cs–2Pd coatings were hydrothermally grown on metastable β-Ti30Zr5Mo, each composition as one batch of three co-processed specimens. XRD, FTIR and Raman spectroscopy indicated a common HA-based calcium-phosphate framework. XPS of one HA–Cs–2Pd specimen identified nitrogen-containing species and oxidized/coordinated Pd; its surface Pd/(Ca + P) atomic ratio (≈0.23) exceeded both the nominal precursor ratio (≈0.007) and the local EDS ratio (≈0.02–0.03), consistent with near-surface Pd enrichment. The apparent coating thicknesses estimated from the cross-sections were 3.8–7.0 µm. Electrochemical data from the two sterilized and cleaned specimens per composition for which records were available, neither exposed to cells or bacteria, agreed on one observation within the tested batches: HA–Cs gave the highest low-frequency impedance (|Z|0.01 Hz = 4.6 × 104 and 5.4 × 103 Ω·cm2) and the lowest approximate corrosion current density (0.66 and 3.8 µA·cm−2), whereas HA–Cs–1Pd and HA–Cs–2Pd showed 1.4- to 4.3-fold lower impedance and about two- to three-fold higher icorr. Specimen-to-specimen variation within a batch was large (up to ninefold); the other composition differences were not reproducible, and no statistical significance was assigned to the ranking. Qualitative Staphylococcus aureus Xen36 bioluminescence (one specimen per composition, previously used for the 4T1 screen) and 4T1 phase-contrast screens did not reveal a consistent Pd-related effect and do not support antibacterial or cytocompatibility claims. Because compositions were not replicated across independent batches, no uncoated control was tested, and the chitosan formulation also introduced acetic acid and additional NH4OH, the data show co-occurring composition-dependent changes in chemistry, morphology and electrochemical response rather than a demonstrated mechanism. Whether the loss of the HA–Cs impedance response on Pd addition reflects an interaction between the constituents requires independently prepared batches; until then, Pd and the chitosan formulation should be evaluated together rather than assumed to be additive.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Graphene Oxide and Palladium Incorporation on Hydrothermally Grown Hydroxyapatite Coatings on β-Ti30Zr5Mo Alloy: Surface Chemistry, Corrosion and Biological Performance.Materials (Basel, Switzerland) · 2026
- Biomimetic deposition of Fe3O4-incorporated hydroxyapatite coatings on Ti-35Nb-7Zr-5Ta alloy with enhanced electrical responseJournal of Alloys and Compounds · 2026
- Development of sol-gel derived fluoridated hydroxyapatite/CaTiO3 composite coating on titanium implant.Journal of materials science. Materials in medicine · 2026
- Bioactive HA/PVDF-HFP nanocomposite coatings for superior corrosion protection of 316 L stainless steel.Colloids and surfaces. B, Biointerfaces · 2026
- Biofunctionalization of SLM Ti–40Nb alloy through hydroxyapatite-modified plasma electrolytic oxidation coatingApplied Surface Science Advances · 2025
- Improvement of Electrochemical Behavior of Nitinol by Hydroxyapatite–Tantalum Oxide Coating Fabricated via Electrophoretic Deposition for Biomedical Applicationsنشریه علمی پژوهشی مواد پیشرفته در مهندسی · 2026