Micromachines

Development and Thermal Characterization of a Mechanically Packaged Hetero-Core Optical Fiber Temperature Sensor.

Eun-Jae Wi, Thien-Dinh Nguyen, Yong-Woon Choi, Jung-Suk Park, Hyoung-Jin Kim, Chang-Woo Kim, Young-Bok Kim

Department of Mechanical System Engineering, the Graduate School, Pukyong National University, Busan 48513, Republic of Korea. · Department of Intelligent Robot Engineering, The Graduate School, Pukyong National University, Busan 48513, Republic of Korea.

Key points

From the paper's conclusion
  • This study presents the development and thermal characterization of a mechanically packaged Hetero-core optical fiber temperature sensor utilizing the thermal expansion of a silicone pad.

Abstract

This study presents the development and thermal characterization of a mechanically packaged Hetero-core optical fiber temperature sensor utilizing the thermal expansion of a silicone pad. To improve the insufficient optical-output recovery observed during cooling in our previous adhesive-fixed sensor, a poly(butylene succinate) (PBS)-based mechanical packaging structure was developed to replace direct adhesive fixation of the Hetero-core sensing region. Thermally induced deformation of the silicone pad produces variations in optical transmission loss, which are detected and converted into electrical voltage signals. Four sensor configurations, combining two silicone pad thicknesses and two Hetero-core insertion lengths, were evaluated using one specimen per configuration through three consecutive heating-cooling cycles over a temperature range of 20-80 °C. The experimental results demonstrated temperature-dependent responses with configuration-dependent differences in linearity, thermal hysteresis, and cycle-to-cycle repeatability. The configuration with a 2 mm thick silicone pad and a 2 mm Hetero-core insertion length exhibited the lowest average hysteresis (15.04% FS), whereas the configuration with a 5 mm thick pad and a 2 mm insertion length showed the lowest heating repeatability error (11.56% FS). The configuration with a 5 mm thick pad and a 3 mm insertion length exhibited the lowest cooling repeatability error (6.12% FS), indicating that the preferred sensor configuration depends on the performance criterion considered. Although further improvements in sensing performance and validation of measurement accuracy, response time, and device-to-device reproducibility are required, the results demonstrate the feasibility of the proposed approach for further development of optical fiber temperature sensors for abnormal-temperature monitoring in electrical equipment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Development and Thermal Characterization of a Mechanically Packaged Hetero-Core Optical Fiber Temperature Sensor — Science Skim