Mitigating Hysteresis in Metal-Coated Fibers via Optimized Thermal Treatment for Advanced Distributed High-Temperature Sensing Applications
Koustav Dey, Rony Kumer Saha, B. Zhang, S. Narasimman, Farhan Mumtaz, Jeffrey D. Smith, Rex E. Gerald, Ronald J. O’Malley,
Missouri University of Science and Technology
Key points
From the paper's conclusion- This work presents the first comprehensive experimental study to systematically investigate and demonstrate the mitigation of hysteresis through an optimized heat treatment process and its underlying mechanisms in metal-coated fibers, supported by microstructural insights.
Abstract
Metal-coated optical fibers are widely employed in sensing applications owing to their superior mechanical strength and corrosion resistance. However, their calibration at elevated temperatures is hindered by hysteresis, manifested as discrepancies between heating and cooling cycles, primarily caused by residual strain from mismatched thermal expansion coefficients (TECs) between the metal coating and silica cladding. This research introduces an optimal heat treatment procedure aimed at minimizing the impact of the mismatch in TECs between the cladding and the coating materials that causes the residual strain in gold (Au) and copper (Cu) coated fibers for achieving reliable distributed high temperature sensing up to 500 °C using Optical Frequency Domain Reflectometry (OFDR) technology. The treatment facilitates stress relaxation and microstructural modifications, including surface diffusion, grain growth and oxidation (for Cu coatings), which collectively induce partial interfacial delamination and thereby suppress hysteresis. This work presents the first comprehensive experimental study to systematically investigate and demonstrate the mitigation of hysteresis through an optimized heat treatment process and its underlying mechanisms in metal-coated fibers, supported by microstructural insights. The identified treatment range of 25–300 °C achieves substantial reductions in residual strain, lowering hysteresis effects by approximately 90.2% in Cu-coated fibers and 86.6% in Au-coated fibers. Furthermore, Au-coated fibers exhibit a consistently lower degree of hysteresis than Cu-coated fibers under comparable thermal conditions. Heat treatment also enhances temperature sensitivity, with improvements of approximately 28.9% for Cu-coated fibers and 6.6% for Au-coated fibers. Post-treatment strain analysis confirms maximum sustainable strain limits of ~6000 με for Au-coated fibers and ~12,000 με for Cu-coated fibers. Both fiber types also demonstrated excellent thermal stability, maintaining consistent performance across three heating cycles between 25 °C and 300 °C over a 20-hour period. Collectively, the findings not only advance the scientific understanding of residual strain relaxation mechanisms but also provide a practical route toward robust, precise, and reliable distributed sensing for demanding industrial environments such as the steel, oil and gas sectors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- All-fiber microheater with attenuation-controlled hot-zone based on metal-doped silica fibers.Optics express · 2026
- Comprehensive Literature Review: Optical Fiber Sensing Technologies for Advanced Low-Temperature and Cryogenic Applications.Sensors (Basel, Switzerland) · 2026
- Localized CO2 Laser-Assisted Hydroxide-Catalysis Bonding for Optical Fiber to Coated Silica IntegrationNanomaterials · 2026
- Comparative Analysis and Optimization of Sensitivity Enhancement Methods for Fiber-Optic Strain Sensors in Structural MonitoringFibers · 2026
- Enhanced Temperature Sensitivity by Nickel-Copper-Coated Optical Fiber in Distributed Sensing Based on Rayleigh Scattering.Sensors (Basel, Switzerland) · 2026
- Development and Thermal Characterization of a Mechanically Packaged Hetero-Core Optical Fiber Temperature Sensor.Micromachines · 2026