Irradiation-Equivalent Injection Test Method for Analyzing HEMP Coupling Effects on Communication Interfaces.
Lu Sun, Peihong Wu, Li Yang, Jin Tian, Zhenxiao Li, Feifei He, Yang Qiu
State Key Laboratory of Electromechanical Integrated Manufacturing of High-Performance Electronic Equipment, School of Electro-Mechanical Engineering, Xidian University, Xi'an 710071, China.
Key points
From the paper's conclusion- By setting up a test system to conduct equivalent injection tests, taking RS232 communication interfaces as a typical representative, the interference threshold of the interface circuits can be accurately obtained.
Abstract
The E1 component of High-altitude Nuclear Electromagnetic Pulse (HEMP) is an electromagnetic wave with extremely high peak power and fast-rising transient fields that can cause irreversible damage to electronic devices in an extremely short period of time. Traditional irradiation tests used to assess its impact on communication interfaces have problems such as high costs and complex system setup. Moreover, HEMP injection test standards and the actual coupling waveforms of the interfaces have significant differences, which leads to inaccurate electromagnetic coupling effect test results and causes problems through unreasonable design of the protection circuit. This study, in combination with the field-line coupling simulation analysis of communication interface circuits, designs a coupling effect test method for irradiation-equivalent injection without the need for high-cost irradiation equipment. By setting up a test system to conduct equivalent injection tests, taking RS232 communication interfaces as a typical representative, the interference threshold of the interface circuits can be accurately obtained. This enables the implementation of targeted and accurate protective measures to ensure the safe use of electronic devices, and has significant engineering application value.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Modeling and experimental study on the response characteristics of typical ports of protective relay equipment under high-altitude electromagnetic pulse.The Review of scientific instruments · 2026
- Effects of Additional Ionization From a High‐Altitude Nuclear Explosion on High Frequency Multipath Propagation and Link AvailabilityRadio Science · 2026
- Damage Mechanism of GaN HEMT and Failure Analysis of Power Amplifier Under High-Altitude Electromagnetic Pulse.Micromachines · 2026
- Experimental Study of Non-Design-Basis Electromagnetic Interference and the Risk of False Operation of Relay Protection at a 500 kV SubstationApplied Sciences · 2026
- Comprehensive TCAD Study of Single-Event Effects in InP HEMTs Under ON-State and RF OperationJournal of Physics D: Applied Physics · 2026
- Failure Characteristics of Electro-Explosive Devices in Strong Magnetic Fields During Electromagnetic LaunchElectronics · 2026