Modeling and experimental study on the response characteristics of typical ports of protective relay equipment under high-altitude electromagnetic pulse.
Mingjia Yan, Shiji Li, Zhi Li, Jianqin Lin, Yujia Hu, Fanchenfei Li, Yichen Han, Qi Gu,
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710024, People's Republic of China. · Zhejiang Huadian Equipment Testing and Research Institute Co., Ltd., Hangzhou 310000, People's Republic of China.
Key points
From the paper's conclusion- The results indicate that the established linear broadband models and the SPD operation model exhibit high reliability.
Abstract
High-altitude electromagnetic pulses (HEMP) can couple into protective relay equipment through external cables, potentially causing hardware damage, function blocking, or logic misoperation. In this paper, the response characteristics of typical ports (power port, digital port, and analog port) of protective relay equipment under HEMP environments are investigated through broadband modeling and pulse injection tests. By measuring S-parameters and employing vector fitting with passivity enforcement, π-type broadband equivalent circuit models for the three typical ports were established. Furthermore, a nonlinear model describing the operation process of surge protective devices (SPD) was constructed. The proposed models were validated through pulse injection simulations and tests under both line-to-line and line-to-ground configurations. The results indicate that the established linear broadband models and the SPD operation model exhibit high reliability. Under line-to-ground injection, the proposed nonlinear model enables indirect identification of abnormal phenomena by comparing simulation and experimental results. Discharge phenomena were observed during the line-to-ground injection tests on the power port No. 2 at 20 and 30 kV, with the corresponding voltage waveforms characterized by a sharp drop.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Irradiation-Equivalent Injection Test Method for Analyzing HEMP Coupling Effects on Communication Interfaces.Micromachines · 2026
- Experimental Study of Non-Design-Basis Electromagnetic Interference and the Risk of False Operation of Relay Protection at a 500 kV SubstationApplied Sciences · 2026
- Comparison of EM Field Developments in a Shielding Enclosure with Aperture After Subnanosecond and Nanosecond Parallel-Polarized Plane-Wave InterferencesApplied Sciences · 2026
- Development and Performance Verification of a Wideband Transient Magnetic-Field Simulation Device for Substation Switching OperationsElectronics · 2026
- Lightning-Induced Wave Processes in a 10 kV High-Voltage Automatic Block SystemTransport automation research · 2026
- Damage Mechanism of GaN HEMT and Failure Analysis of Power Amplifier Under High-Altitude Electromagnetic Pulse.Micromachines · 2026