Micromachines

A Large-Aperture Variable Iris Directly Driven by a V-Shaped Mode-Coupled Ultrasonic Motor: Design, Optimization, and Experimental Validation.

Benchao Lv, Jun Zhao, Hongsheng Sun, Xucong Bao, Tong Zhao, Xiaolin Wang, Zhiyuan Yao, Xinjian Li,

National Key Laboratory of Infrared Detection Technologies, Shanghai 200083, China. · Kunming Physics Research Institute, Kunming 650223, China.

Key points

From the paper's conclusion
  • This study presents a laboratory prototype of a 20-blade iris directly driven by a V-shaped mode-coupled ultrasonic motor.

Abstract

Large-aperture variable irises must provide continuous aperture regulation within a restricted axial space. This study presents a laboratory prototype of a 20-blade iris directly driven by a V-shaped mode-coupled ultrasonic motor. The iris was geometrically designed for a 5.5 mm-98 mm clear-aperture range. A wave-spring-bearing compliant preload mechanism was designed to maintain blade compression while permitting low-resistance actuating-ring rotation. Under a 3 N axial load, finite-element analysis showed that a representative three-blade overlap unit was approximately 7.6 times stiffer axially than the preload mechanism, so deformation occurred mainly in the latter. Taguchi design and multi-objective optimization produced a flexibly clamped stator with simulated working modes at 121.93 kHz and 122.10 kHz, separated by 170 Hz; the measured frequencies were 120.7 kHz and 121.5 kHz. At 121.8 kHz and 300 Vpp, the 5.74 g stator generated bidirectional maximum thrusts of 3.91 N and 4.11 N, corresponding to a maximum thrust-to-mass ratio of 716 N/kg. A separate short-cycle test yielded a minimum observed stable tangential displacement of 3.23 μm. Quantitative opening and closing tests over a local 10 mm-20 mm interval yielded mean absolute actuating-ring angle errors of 0.087° and 0.13°, respectively. Model-extrapolation tests from a 20 mm reference yielded an aperture MAE of 0.183 mm over 10 mm-80 mm, while errors of 1.7 mm and -1.2 mm were measured at the 5.5 mm and 98 mm targets. These results support the functional feasibility of the proposed direct-drive architecture and identify an increased prediction error near the travel limits.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Large-Aperture Variable Iris Directly Driven by a V-Shaped Mode-Coupled Ultrasonic Motor: Design, Optimization, and Experimental Validation — Science Skim