Key points
From the paper's conclusion- This study presents a structured framework for industrial wear quantification using optical three-dimensional (3D) metrology.
Abstract
Tool wear in progressive sheet-metal stamping can affect product geometry, process stability, and maintenance requirements. Reliable quantitative assessment under industrial production conditions remains challenging because wear can be highly localized and conventional inspection methods provide limited spatial information. This study presents a structured framework for industrial wear quantification using optical three-dimensional (3D) metrology. The framework combines repeated optical surface acquisition, reference-based registration, region-specific deviation analysis, and quantitative evaluation of wear-related geometry changes under production conditions. The framework was evaluated on wear-critical bending inserts investigated at defined production stages. Optical 3D profile evaluation revealed deviations of 0.044 mm after 5 million production cycles, 0.061 mm after 10 million cycles, and 0.094 mm after 15 million cycles. The corresponding measured component bending angles were 90.6° in the initial state and 91.6°, 92.7°, and 94.4° at the respective production stages. Complementary SEM observations revealed localized differences in surface condition, while the 3D deviation maps demonstrated that the measured geometry changes were spatially non-uniform. Measurement system capability was additionally assessed using a Type 1 study and an extended repeatability investigation. For the calibrated three-sphere reference standard, the observed measurement ranges were 0.0071–0.0111 mm, with Cg values of 2.39–2.62 and Cgk values of 1.33–1.45. The results support the use of the measurement chain for comparative assessment of different tool states, while also demonstrating the need for task-specific uncertainty evaluation before binding wear or replacement limits are introduced. The principal contribution of the study is a reproducible industrial workflow that combines spatially resolved optical measurements with quantitative tool-condition assessment while limiting interference with production. The framework provides a basis for documented tool monitoring and future condition-based maintenance strategies but does not yet establish a validated wear limit or predictive replacement criterion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Iterative Calibration of an Archard Wear Model from Production Data: Framework, Industrial Validation and Transferability Assessment for Sheet Metal StampingApplied Sciences · 2026
- From acquisition errors to reliable data: the quantitative-qualitative validation method for surface topography studiesSurface Topography: Metrology and Properties · 2026
- Profilometric Measurement of Wear Scar Volume After Abrasive Resistance Test.Materials (Basel, Switzerland) · 2026
- Statistical and Metrological Framework for Evaluation of micro-CT 3D Data with Application to Dental Implant ComponentsMeasurement Science Review · 2026
- A Hybrid-Level Weighted Multi-View Measurement Method for Industrial Geometric Features.Sensors (Basel, Switzerland) · 2026
- Advances in Measurement Methods and Optimization Strategies for Large-Volume Cylindrical Components: A ReviewApplied Sciences · 2026