Statistical and Metrological Framework for Evaluation of micro-CT 3D Data with Application to Dental Implant Components
Miroslav Hain, Alexander Šatka, Tomáš Czán, Andrej Czán, Mário Drbúl, Jaromír Markovič, Viktor Witkovský
Key points
From the paper's conclusion- We apply a statistical and metrological framework to signed CAD–CT deviations at the vertices of three geometrically different titanium dental implant components, D1–D3, representing complex surface geometry, substantial μ CT-to-CAD deviations, and ambiguous initial alignment.
Abstract
Dimensional comparison of micro-computed tomography (micro-CT) reconstructions with CAD geometry requires a precise definition of the evaluated surface points. We apply a statistical and metrological framework to signed CAD–CT deviations at the vertices of three geometrically different titanium dental implant components, D1–D3, representing complex surface geometry, substantial μ CT-to-CAD deviations, and ambiguous initial alignment. Complete exports contain 75 812, 46 954, and 16 416 measured-surface vertices. The corresponding RMS deviations are 49.14 μ m, 207.72 μ m, and 77.07 μ m. Empirical cumulative distribution functions, histograms normalized to unit area, and descriptive summaries compare the observed meshes; two-sample Kolmogorov–Smirnov (KS) distances quantify differences between their vertex distributions. D2 has the largest absolute-deviation upper tail. A detailed axial analysis of D1 localizes all 267 vertices with absolute deviation above 200 μ m in one of 12 intervals. Separate area-sampled and radial D1 exports provide sensitivity checks for alternative surface and correspondence definitions. Because vertices are spatially dependent and mesh density determines their weighting, conventional KS p -values are only nominal reference calculations. A prospective observation model distinguishes physical deviation from measurement and alignment effects. The workflow provides a reproducible basis for statistical evaluation and measurement-uncertainty assessment of individual components.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimising digital volume correlation across materials: a practical framework for accuracy and spatial resolutionbioRxiv · 2026
- Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body-independent technique.The Journal of prosthetic dentistry · 2026
- Accuracy and Fit of Three-Unit Dental Restorations Fabricated from 3D-Printed Resins and CAD/CAM Milling Materials: A Micro-CT StudyBioengineering · 2026
- Accuracy is a behavior, not a number: a metrological reporting framework for complete-arch implant scanningJournal of Dentistry · 2026
- Micro-computed tomography enables in vitro 3D quantification of denture adhesive behavior at denture-mucosa interfaceFrontiers in Biomaterials Science · 2026
- Effect of Fiducial Marker Design (Shape, Size, and Configuration) on the Trueness and Precision of CBCT Marker-Geometry Reproduction for CBCT-Intraoral Scan Registration: An In Vitro Study.Diagnostics (Basel, Switzerland) · 2026