From the paper's conclusion- Purpose: To quantify refractive and distance visual changes between 3 and 12 months after bilateral Artis Symbiose multifocal intraocular lens (IOL) implantation.
Abstract
Purpose: To quantify refractive and distance visual changes between 3 and 12 months after bilateral Artis Symbiose multifocal intraocular lens (IOL) implantation. Methods: This retrospective study included 277 patients (554 eyes) undergoing cataract surgery or refractive lens exchange, selected for complete primary postoperative outcomes; indication-specific counts were unavailable. Postoperative-only mixed-effects models included participant and nested-eye random intercepts. Patient-cluster inference and paired patient-level analyses assessed sensitivity. Exploratory equivalence tests were performed using predefined margins, while changes were quantified separately for each eye. Results: Mean sphere increased by +0.114 D (95% CI +0.084 to +0.143) and spherical equivalent (SEQ) by +0.104 D (95% CI +0.078 to +0.131); both remained significant after Holm adjustment (p < 0.001). Cylinder changed by −0.019 D (95% CI −0.041 to +0.004; adjusted p = 0.190). Changes in uncorrected and corrected distance visual acuity were +0.0083 and +0.0055 logMAR, respectively, and were not significant after adjustment. Exploratory tests supported mean changes within ±0.25 D for SEQ and ±0.05 logMAR for uncorrected distance acuity. Absolute within-eye SEQ changes were ≤0.25, ≤0.50 and ≤1.00 D in 75.6%, 94.6% and 99.5% of eyes, respectively. Analyses restricted to 267 recorded complementary MID/Plus pairs yielded comparable conclusions. Conclusions: Small, statistically detectable hyperopic shifts occurred between the recorded postoperative visits. Mean changes remained within the exploratory equivalence bounds, but this does not establish stability in every eye or comprehensive functional stability of the lens system.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Comparative Study of the Visual Outcomes of Two Common Diffractive Trifocal Intraocular Lenses in a Matched Cohort.Cureus · 2026
- Postoperative effective lens position and refraction changes with three different types of intraocular lensInternational Journal of Ophthalmology · 2026
- Visual Performance, Optical Quality, and Patient-Reported Outcomes After Trifocal Lens Implantation in Patients With Clear Lens or Early Cataract.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses.Journal of clinical medicine · 2026
- Comparative Clinical Outcomes Between Successive Generations of Liberty Trifocal Intraocular Lenses.Journal of clinical medicine · 2026
- 12-Month Visual and Clinical Outcomes After Implantation of a Monofocal Aspheric Hydrophobic Acrylic IOL: A Prospective Feasibility Study.Clinical ophthalmology (Auckland, N.Z.) · 2026