Short- and Long-Term Dynamics of Endothelial Cell Density and Vault Changes After Implantable Collamer Lens Implantation.
Maria Muzyka-Woźniak, Adam Oleszko, Malwina Terlecka
Research and Development Center CREO, Clinical Ophthalmology Center SPEKTRUM, Zaolzianska 4, 53-334 Wroclaw, Poland.
Key points
From the paper's conclusion- Background/Objectives: Endothelial cell density (ECD) and vault height are essential safety metrics in implantable collamer lens (ICL) surgery, yet their reported decay rates vary.
Abstract
Background/Objectives: Endothelial cell density (ECD) and vault height are essential safety metrics in implantable collamer lens (ICL) surgery, yet their reported decay rates vary. This study assessed short- and long-term changes in ECD and vault height. Methods: Medical records of patients undergoing V4c ICL implantation between 2014 and 2024 were reviewed. ECD loss was evaluated across three periods: early (baseline to 6 months), late (6 months to last visit), and total (baseline to last visit). Vault was measured at day 1 and months 3, 6, 12, and the last visit and decay rate was calculated for the entire follow-up period. Results: A total of 631 eyes of 323 patients were analyzed. The early, late, and total ECD losses per year were 1.81 ± 8.56% (95% CI 0.43 to 3.19), 0.68 ± 2.11% (95% CI 0.34 to 1.03), and 1.21 ± 2.58% (95% CI 0.83 to 1.59), respectively. The ECD loss rate was not correlated with vault. Vault decreased rapidly during the first 3 postoperative months (-178.0 µm/year; 95% CI, -211.4 to -144.6; p < 0.001), followed by a substantially slower but still significant decline (-19.1 µm/year; 95% CI, -23.9 to -14.2; p < 0.001). The difference between the early and late slopes was significant (p < 0.001). The vault decay rate was 6.80 ± 10.41% (95% CI, 5.48 to 8.13%) per year and was not associated with ICL size or anterior chamber depth. Conclusions: ECD loss was greatest and most variable during the first 6 months postoperatively. Thereafter, a slower sustained decline was observed. Vault decay showed a biphasic pattern, with a relatively rapid decrease during the first 3 postoperative months and a significantly slower long-term decline.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term Efficacy and Safety of the Implantable Collamer Lens in Eyes With an Anterior Chamber Depth of 2.6 to 2.8 mm.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Long-term evaluation of anterior segment structures after implantable collamer lens V4c implantation.International ophthalmology · 2026
- Intraoperative OCT observation of incision-related descemet membrane detachment during implantable collamer lens implantation.Frontiers in medicine · 2026
- Clinical Outcomes of Implantable Collamer Lens Implantation in Eyes with Very Low and Low Postoperative Vault: A Retrospective Cohort Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Anterior Chamber Depth and the Long-Term Safety of Implantable Collamer Lens Surgery: A Case for Re-Evaluating Age-Stratified Indication Criteria.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Biometric and ICL-related risk factors associated with suboptimal vault with implantable collamer lenses.Frontiers in medicine · 2026