Anterior Chamber Depth and the Long-Term Safety of Implantable Collamer Lens Surgery: A Case for Re-Evaluating Age-Stratified Indication Criteria.
Keizo Watanabe
Department of Ophthalmology, Minami Osaka Eye Clinic, Kumatori, Japan.
Key points
From the paper's conclusion- Current criteria reflect the eye's status at a single time point. We suggest age-stratified ACD values be used as risk-stratification factors alongside gonioscopy and anterior segment imaging, not as standalone exclusion criteria, in parallel with established corneal refractive surgery criteria. Long-term validation is warranted.
Abstract
PURPOSE: Implantable Collamer Lens (ICL) surgery is mostly performed in patients aged 20-40, with current minimum anterior chamber depth (ACD) eligibility of approximately 2.8-3.0 mm. A shallow chamber carries two distinct long-term risks: corneal endothelial cell loss, determined principally by the endothelium-to-implant distance, and angle closure, determined by progressive anterior segment crowding. This static criterion accounts for neither of the two dynamic factors that reduce effective ACD over decades: age-related crystalline lens thickening, and vault-related anterior displacement of the implant. We propose age-stratified ACD values, anchored to the empirical 2.4 mm threshold for primary angle closure in East Asians, as risk-stratification factors. METHODS: We conducted a structured narrative review of ACD and primary angle-closure disease in East Asians including Japanese data; age-related anterior segment biometry; vault dynamics; and long-term ICL outcomes, integrated into a quantitative model presented as a conservative estimate rather than a definitive predictor. RESULTS: The 2.4 mm threshold is confirmed in East Asian populations and consistent with Japanese population-based biometry. ACD shallows at approximately 0.011-0.012 mm/year; vault contributes a further functional reduction of approximately 0.25-0.40 mm. A patient implanted at age 20 with an initial ACD of 2.8 mm may approach 2.0 mm by age 60. Age-stratified minimum values of 3.2, 3.1 and 3.0 mm for the third, fourth and fifth decades preserve a margin above 2.4 mm; sensitivity analysis across lens-extraction ages of 45-60 years yields 3.0-3.2 mm. Independently, ten-year data in eyes with ACD below 2.8 mm show endothelial loss at approximately twice the physiological rate. CONCLUSION: Current criteria reflect the eye's status at a single time point. We suggest age-stratified ACD values be used as risk-stratification factors alongside gonioscopy and anterior segment imaging, not as standalone exclusion criteria, in parallel with established corneal refractive surgery criteria. Long-term validation is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term Efficacy and Safety of the Implantable Collamer Lens in Eyes With an Anterior Chamber Depth of 2.6 to 2.8 mm.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Long-term evaluation of anterior segment structures after implantable collamer lens V4c implantation.International ophthalmology · 2026
- Short- and Long-Term Dynamics of Endothelial Cell Density and Vault Changes After Implantable Collamer Lens Implantation.Medical sciences (Basel, Switzerland) · 2026
- Biometric and ICL-related risk factors associated with suboptimal vault with implantable collamer lenses.Frontiers in medicine · 2026
- Development and Clinical Evaluation of an Anterior Chamber Angle-Based Lens Sizing Method for Implantable Collamer Lens Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Clinical Outcomes of Implantable Collamer Lens Implantation in Eyes with Very Low and Low Postoperative Vault: A Retrospective Cohort Study.Clinical ophthalmology (Auckland, N.Z.) · 2026