Feasibility of i-Gel Airway Management During Awake Craniotomy Using the Asleep-Awake-Asleep Method: A Retrospective Study.
Yui Somura, Takehito Sato, Shigeru Inoue, Koichi Akiyama
Department of Anesthesiology, Nagoya University Hospital, Nagoya 4668560, Aichi, Japan.
Key points
From the paper's conclusion- Overall, both asleep phases were completed using the i-gel alone in 345/366 patients (94.3%).
Abstract
Background and Objectives: The i-gel is a second-generation supraglottic airway device that may be suitable for repeated airway management during awake craniotomy (AC) using the asleep-awake-asleep (AAA) technique. This study evaluated the feasibility of using the i-gel for airway management during AC. Materials and Methods: This single-center retrospective study included 366 patients in whom AC for brain tumor resection using the AAA technique was planned. The primary outcome was the overall success rate of i-gel-only airway management. Secondary outcomes included success rates during each asleep phase, rescue airway strategies, airway-related adverse events, and factors associated with second-phase failure. Results: Initial-phase i-gel management was successful in 363/366 patients (99.2%). Among these 363 patients, second-phase i-gel management was successful in 345 (95.0%). Overall, both asleep phases were completed using the i-gel alone in 345/366 patients (94.3%). Of the 18 second-phase failures, 10 involved inadequate ventilation despite successful insertion, and eight involved difficult or failed reinsertion. Rescue airway management was successful in all 18 patients, including seven patients who underwent fiberoptic-guided tracheal intubation through the i-gel. No severe hypoxemia or clinically significant airway injury occurred. Initial suboptimal i-gel fit was associated with second-phase failure (adjusted odds ratio, 7.05; 95% confidence interval, 2.58-18.97; p < 0.001). Conclusions: The i-gel provided successful airway management in most patients undergoing AC with the AAA technique. An initially suboptimal fit may serve as a warning signal for second-phase failure, and appropriate rescue airway strategies should be readily available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical performance of i-gel and classic laryngeal mask airway in different head positions in patients aged ≥75 years: A prospective randomized study.The Journal of international medical research · 2026
- I-gelTM Plus implements higher oropharyngeal leak pressure in the lateral decubitus position than original i-gelTM: a prospective randomized controlled trial.Anaesthesia, critical care & pain medicine · 2026
- Oropharyngeal leak pressure of the Ambu® AuraGain™ versus Flexicare® LarySeal™ Pro in ophthalmic surgery: a randomized controlled trialMinerva Anestesiologica · 2026
- A novel endoscopy-guided airway management strategy for lateral decubitus endoscopic procedures.Frontiers in medicine · 2026
- Awake Double-Lumen Endotracheal Tube Intubation With Preserved Spontaneous Ventilation for Laparoscopic Repair of a Giant Type IV Hiatal Hernia: A Case Report.A&A practice · 2026
- Hybrid Spinal-General Anesthesia With a Supraglottic Airway in Severe Rheumatoid Arthritis: A Case Report.Cureus · 2026