Pulmonary Vein Isolation with Different Single-Shot Ablation Devices in Patients with Atrial Fibrillation: A Prospective Observational Single-Center Clinical Evaluation.
Wiktor Czarkowski, Bartłomiej Popielarz, Agata Kukfisz, Michał Skrzypek, Mariusz Gąsior, Krzysztof Myrda
2nd Department of Cardiology and Angiology, Silesian Centre for Heart Diseases, 41-800 Zabrze, Poland. · Department of Biostatistics, Faculty of Public Health in Bytom, Medical University of Silesia, 40-055 Katowice, Poland.
Key points
From the paper's conclusion- Conclusions: In this single-center observational study, PVI performed with PFA was associated with the shortest procedure time compared with procedures using CBA or RFB, with no difference in the risk of arrhythmia recurrence among the single-shot ablation modalities during the 12-month follow-up.
Abstract
Background and Objectives: The conventional technique for atrial fibrillation (AF) ablation has gradually been supplemented by 'single-shot' devices. Comparisons of devices using three different energy sources are rare. We aimed to evaluate the outcomes of patients with AF who underwent pulmonary vein isolation (PVI) using three various single-shot ablation techniques. We also examined factors associated with arrhythmia recurrence during the 12-month follow-up. Materials and Methods: We prospectively analyzed single-center data from consecutive adult patients undergoing PVI with different single-shot devices between January and December 2024. For cryoablation, a second-generation cryoballoon (AFA, Medtronic, Minneapolis, MN, USA) was used; for radiofrequency balloon ablation, the RFB catheter (Heliostar, Biosense Webster, California, CA, USA) was applied; and for the PFA-guided procedure, the Farawave (Boston Scientific, Massachusetts, MA, USA) ablation catheter was used. The procedural endpoint was to achieve intraoperative PVI. Arrhythmia recurrence was defined as any episode lasting >30 s documented by electrocardiographic recordings. Results: Ultimately, the analysis included 115 patients. Of these, 41 underwent PVI by cryoablation, 22 underwent RFB therapy, and 52 underwent PFA. The total skin-to-skin procedure time was the shortest among PFA-patients, primarily due to shorter left atrial dwell time. After 12 months of follow-up, 30 patients experienced recurrence of atrial arrhythmia. A larger left atrium diameter increased the risk of arrhythmia recurrence, whereas propafenone therapy at discharge was associated with a lower risk of recurrence during the 12-month follow-up. Conclusions: In this single-center observational study, PVI performed with PFA was associated with the shortest procedure time compared with procedures using CBA or RFB, with no difference in the risk of arrhythmia recurrence among the single-shot ablation modalities during the 12-month follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative one-year outcomes of pulmonary vein isolation and roof line ablation using cryoballoon versus pulsed-field ablation in persistent atrial fibrillation with left atrial dilatationEuropean Heart Journal · 2026
- Catheter ablation of atrial fibrillation using the pulsed-field energy; a prospective randomized comparison of the CENTAURI PEF system and the FARAPULSE SystemEuropean Heart Journal · 2026
- From trial to practice: early multicenter real-world experience with the circular pulsed field ablation catheterJournal of Interventional Cardiac Electrophysiology · 2026
- Real-world one-year effectiveness of three pulsed field ablation systems for atrial fibrillationEuropean Heart Journal · 2026
- Procedural characteristics and acute outcomes with different pulsed field ablation systems for atrial fibrillationJournal of Interventional Cardiac Electrophysiology · 2026
- Catheter ablation of atrial fibrillation using the pulsed-field energy; a prospective randomized comparison of CENTAURI PEF pef system and radiofrequency ablationEuropean Heart Journal · 2026