Impact of Moisture-Buffering Materials and Time-Averaging of Infiltration Rate on Prediction of Indoor Air Humidity.
Dobrosława Kaczorek, Małgorzata Basińska, Tomasz Kisilewicz, Katarzyna Nowak
Thermal Physics, Acoustics and Environment Department, Building Research Institute (ITB), Filtrowa 1 Str., 00-611 Warsaw, Poland. · Faculty of Environmental Engineering and Energy, Institute of Environmental Engineering and Building Installations, Poznan University of Technology, Berdychowo 4 Str., 61-131 Poznan, Poland.
Key points
From the paper's conclusion- The annual mean infiltration rate was 0.117 h−1, while selected daily means ranged from 0.03 to 0.60 h−1.
Abstract
The moisture buffering properties of materials and actual air exchange are crucial for indoor conditions in buildings. Consequently, precise material data and an adequate model of highly variable outdoor air infiltration are essential for computer-based design simulations. This study quantifies how internal cladding materials and infiltration time-averaging affect indoor relative humidity prediction. Three internal finishing variants were analysed: painted gypsum plasterboard, painted clay board, and unpainted clay board, the latter characterised experimentally by a practical moisture buffer value of 1.88 g/(m2·%RH). Three moisture-load scenarios were considered, resulting in 27 simulation cases. Hourly infiltration rates were calculated in the DesignBuilder software and then converted into annual, monthly, and daily averages for WUFI Plus 3.X simulations. The annual mean infiltration rate was 0.117 h-1, while selected daily means ranged from 0.03 to 0.60 h-1. Passive moisture buffering, especially the unpainted clay board, reduced short-term RH fluctuations but did not entirely compensate for insufficient moisture removal. Surface finishing has a decisive influence on the practical performance of hygroscopic materials. Under high moisture gains, median RH reached about 69.5%, and predictions became sensitive to infiltration resolution. Annual averaging may therefore be sufficient for low moisture loads, whereas daily values are required when short-term moisture peaks and moisture buffering effects are relevant.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Environmental Factors and Microstructure on Water Vapor Permeability of Gypsum-Based Inorganic Mineral Materials.Materials (Basel, Switzerland) · 2026
- Computational Hygrothermal Analysis of External Wall Behavior in Naturally Ventilated and Air-conditioned Historical Buildings in ThailandNakhara Journal of Environmental Design and Planning · 2026
- A Damage-Spectrum Framework for Specifying the Indoor Climate of Historic BuildingsBuildings · 2026
- The Significance of Using Temperature-Dependent Material Properties in Hygrothermal Performance Assessment of Exterior Wall SystemsBuildings · 2026
- Testing Natural Knitted Membranes, hygroscopic and UV resistance, for Cultural Heritage protectionce/papers · 2026
- Material Performance and Environmental Response in Historic Masonry Buildings: A Multicenter Longitudinal Observational Study.Journal of visualized experiments : JoVE · 2026