Degradation of Electrical Performance in Transformer Oil Under Low-Temperature Moist Conditions and Its Microscopic Mechanisms.
Tonglei Wang, Tianxi Xie, Yuxing Chen, Zhengguang Chen, Qi Shi
Electric Power Research Institute, State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China. · State Key Laboratory of Electric Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China.
Key points
From the paper's conclusion- The results establish a link between temperature-dependent moisture aggregation and macroscopic electrical degradation, providing a microscopic explanation for the anomalous temperature-dependent insulation behavior.
Abstract
Low-temperature environments pose challenges to transformer insulation reliability, as altered solubility and physical states of moisture in oil may trigger degradation mechanisms absent at ambient temperatures, yet the physicochemical processes remain poorly understood. This study combines macroscopic measurements with molecular dynamics (MD) simulations to investigate the bulk conductivity and alternating current (AC) breakdown characteristics of moist transformer oil across a wide temperature range. Conductivity and breakdown voltage were measured under controlled cooling conditions, while MD simulations tracked water cluster evolution and interfacial behavior at the molecular level. The results reveal a non-monotonic temperature dependence: conductivity exhibits a single-peak maximum near -5 °C, whereas breakdown strength reaches a pronounced minimum around -10 °C, with an offset between the two phenomena. MD simulations demonstrate that, as temperature decreases, water molecules transition from a dispersed state to nucleated aggregates and eventually form stable large-scale clusters. The low-temperature-induced nucleation and aggregation of moisture, which are much less pronounced under normal-temperature conditions, increase the oil-water interfacial area and enhance interfacial polarization, contributing to the anomalous increase in conductivity. At lower temperatures, stable water clusters act as dielectric "soft defects", inducing local electric field distortion and thereby reducing the breakdown strength. The results establish a link between temperature-dependent moisture aggregation and macroscopic electrical degradation, providing a microscopic explanation for the anomalous temperature-dependent insulation behavior. These findings help to optimize insulation design and develop condition-assessment strategies for transformers in frigid regions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Micro-Water Migration Characteristics in Cable Oil-Filled Terminations and Their Effect on Insulation PerformanceEnergies · 2026
- Low-Temperature Negative Lightning Impulse Breakdown in Ester and Mineral Oils: Viscosity–Voltage Correlation and Streamer BranchingIEEE Transactions on Dielectrics and Electrical Insulation · 2026
- Decay products and contaminants in transformer insulation: Mechanisms, dielectric impacts, and sustainable regeneration strategiesNext Sustainability · 2026
- Gas-Generation Characteristics of Mineral Oil, Natural Ester and Synthetic Ester Under Multiple Partial-Discharge Regimes: Implications for Dissolved Gas AnalysisProcesses · 2026
- Adsorption and Sensing Mechanisms of Transformer Dissolved Gases on Transition Metal-Doped MoTe₂ Monolayers: A DFT StudyLangmuir · 2026
- Numerical investigation of discharge-induced pressure waves in insulation oil via sequential Keller-Miksis methodJournal of Physics D: Applied Physics · 2026