Mechanical Non-Equivalence of Imposed-Strain Representations in Bond-Slip Modelling of Restrained RC Ties.
Mariusz Zych
Faculty of Civil Engineering and Transport, Cracow University of Technology, 31-155 Cracow, Poland.
Key points
From the paper's conclusion- The results are interpreted in terms of evolving transfer lengths and tension stiffening.
Abstract
Imposed deformations caused by shrinkage and temperature are a major source of early-age and serviceability cracking in restrained reinforced concrete (RC) members, including tanks, water-retaining structures and containment structures. A bond-slip-based finite-element framework is presented for simulating crack initiation, stepwise crack formation, crack-width evolution and reinforcement-stress histories in end-restrained RC ties. Three practically relevant representations of imposed deformation are compared: end-displacement-controlled axial deformation, prescribed shrinkage-type eigenstrain in concrete and thermal loading-inducing strains in concrete and reinforcement. The displacement-controlled model is validated against corresponding laboratory tests, whereas the shrinkage- and temperature-based representations are examined as comparative numerical scenarios under nominally equivalent imposed-strain levels. The results are interpreted in terms of evolving transfer lengths and tension stiffening. It is demonstrated through the analyses that matching a nominal imposed-strain level does not ensure mechanical equivalence between the three loading representations considered. Although the three approaches may produce comparable final crack widths in some of the analysed cases, they result in markedly different reinforcement-stress histories, transfer-length evolution and steel-concrete force redistribution. This distinction is important when the crack-width analysis is coupled with reinforcement-stress assessment or when imposed strains are superposed with mechanical loading.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Concrete Shrinkage Behavior Under Varying Degrees of Restraints Using DIC.Materials (Basel, Switzerland) · 2026
- The modified tension chord model for reinforced concrete structures in service conditions: Accounting for the effects of internal cracks and concrete coverStructural Concrete · 2026
- Bond-Transfer-Controlled Crack-Width Modelling of Reinforced Concrete as a Cement-Based Composite Under Imposed Strains.Materials (Basel, Switzerland) · 2026
- Research on Cracking Causes of Industrial Roof Slabs and Optimized CFRP Strengthening Measures.Materials (Basel, Switzerland) · 2026
- Short- and long-term deflections of RC slabs strengthened with CFRP systems under sustained loading and different environmental conditioningEngineering Structures · 2025
- Assessment and design of restrained reinforced concrete beams subjected to hysteresis elongation effectsEngineering Structures · 2025