An Accelerated Concrete Prism Test for Evaluating Fly Ash Mitigation of Alkali-Silica Reaction in Reactive Tuff Aggregates.
Xiaojun Liu, Yan Zhang, Guangye Lv, Wei Li, Xiaojun Huang, Min Deng
China General Nuclear Power Corporation, Shenzhen 518000, China. · School of Architectural Engineering, Nanjing Institute of Technology, Nanjing 211167, China.
Key points
From the paper's conclusion- The results show that ACPT can distinguish the mitigation performance of different fly ash replacement levels within a specified test period.
Abstract
The concrete prism test (CPT) retains the aggregate size and specimen configuration of concrete and is widely used to evaluate measures for mitigating alkali-silica reaction (ASR). However, it requires a long test period, and stable control of moist-air curing conditions can be difficult. To improve the efficiency of concrete-scale ASR assessment, four reactive tuffs were investigated using the accelerated mortar bar test (AMBT), standard CPT, and an accelerated concrete prism test (ACPT) involving immersion in 1 mol/L NaOH at 80 °C. Grade I Class F fly ash was used at replacement levels of 0-35%, and the reaction characteristics of the tuff aggregates were examined by microscopy. With 15% fly ash, the 28 d AMBT expansions decreased from 0.212 to 0.376% to 0.036-0.050%, while the 728 d CPT expansions decreased from 0.037 to 0.064% to 0.018-0.029%. All values were below the corresponding expansion limits. The ACPT retained the concrete prism geometry and coarse aggregate grading while accelerating ASR under high-temperature alkaline exposure. The minimum fly ash replacements required to keep all tuff concretes below 0.040% were 20% at 182 d and 30% at 273 d. At 364 d, no replacement level up to 35% met this criterion for all mixtures. As the fly ash replacement increased from 0% to 15% and 35%, the visibly reacted depth of the tuff aggregate decreased from approximately 12 mm to 7 mm and 5 mm, respectively, consistent with the reduction in prism expansion. The results show that ACPT can distinguish the mitigation performance of different fly ash replacement levels within a specified test period. Its expansion criterion should therefore be linked to a fixed assessment age. The 182 d result may be used for rapid dosage selection, whereas the 273 d result provides a stricter recommendation for structures with higher durability and safety requirements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Determining the efficiency of SCMs in reducing ASR-driven solidification pressure through coupled microstructural analysis and thermodynamic modellingCement and Concrete Composites · 2025
- Effect of fly ash content on the leaching resistance of shotcreteFrontiers in Materials · 2026
- Development of Alkali-Activated Phosphogypsum Mortar Incorporating Silica Fume and Metakaolin for Enhanced Durability and CO 2 MineralisationIOP Conference Series: Earth and Environmental Science · 2026
- Creep behavior of lightweight concrete containing fly ash ceramsite aggregate after exposure to high temperaturesScientific Reports · 2026
- Carbonation Curing and Mechanical Properties of Alkali-Activated Composites Derived from Calcined Granite Waste and Waste Ceramic PowderBuildings · 2026
- Enhancing CO2 Mineralization and Mechanical Performance of Fly Ash-Based Alkali-Activated Mortar Using Calcined Seashell Ash.Materials (Basel, Switzerland) · 2026