Assessment of the Influence of Environmental Conditions on the Corrosion Rate of Reinforcing Bars in Concrete Made with Two Different Cements.
Wioletta Raczkiewicz, Kamil Bacharz, Albert Grajek
Faculty of Civil Engineering and Architecture, Kielce University of Technology, Al. 1000-lecia PP 7, 25-314 Kielce, Poland.
Key points
From the paper's conclusion- Two concrete mixtures differing only in cement type (CEM III and CEM V) were prepared and evaluated for reinforcement corrosion.
- CEM V cement may constitute an alternative to CEM III cement under conditions of chloride ion exposure and freeze-thaw cycles.
- The potential environmental benefits of CEM V cement are supported by lower CO2 emissions.
Abstract
In recent years, low-carbon concretes have undergone intensive development in response to the need to reduce CO2 emissions, particularly in the construction sector. One of the approaches to reducing the carbon footprint is the use of blended cements, including blast furnace cement CEM III containing a significant proportion of ground granulated blast furnace slag and composite cement CEM V. The aim of the study was to evaluate the effect of CEM III and composite cement CEM V on reinforcement corrosion and selected properties of structural concrete. Two concrete mixtures differing only in cement type were prepared. The experimental program included the evaluation of reinforcement corrosion activity using the Galvanostatic Pulse Method (GPM) on reinforced concrete specimens exposed to different environmental conditions. Additional tests included compressive strength, modulus of elasticity, shrinkage, freeze-thaw resistance, and water absorption. Based on the results obtained, it was concluded that, under the investigated conditions, namely exposure of reinforced concrete specimens to chloride ions and freeze-thaw cycles, CEM V cement may constitute an alternative to CEM III cement. This is particularly relevant because the potential environmental benefits associated with the lower CO2 emissions of concretes containing CEM V cement are supported by the available literature. Nevertheless, to verify this assumption, more detailed studies on the durability of reinforced concrete structures are required.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- Two concrete mixtures differing only in cement type (CEM III and CEM V) were prepared and evaluated for reinforcement corrosion.
- CEM V cement may constitute an alternative to CEM III cement under conditions of chloride ion exposure and freeze-thaw cycles.
- The potential environmental benefits of CEM V cement are supported by lower CO2 emissions.
Readers' thoughts
No reader thoughts yet.
Related papers
- Corrosion of Embedded Carbon Steels, Carbonation and Chloride Diffusion in Low-Clinker Hybrid and LC3-50 Cements: A Critical Review.Materials (Basel, Switzerland) · 2026
- Comparative Cradle-to-Gate Carbon Footprint Assessment of Selected Cementitious and Alkali-Activated CompositesBuildings · 2026
- Beyond CEM II/C‐M cements: advancing towards hybrid binders with ultra‐low clinker contentce/papers · 2026
- Durability of concrete according to performance concept – influence of the main cement constituents on material properties of concretece/papers · 2026
- Multi-performance assessment of sodium carbonate-based low-alkali binder concrete under ambient and controlled ambient curing conditionsNext Materials · 2026
- Life Cycle Assessment of Reinforced Concrete Structures using Pozzolanic MaterialsEngineering Research Express · 2026