Materials (Basel, Switzerland)

Three-Dimensional Evaluation of Marginal Gap in Prefabricated Zirconia and 3D-Printed Pediatric Crowns.

Büşra Karaağaç Eskibağlar, İrem İpek, Ayşe Rençber Kızılkaya

Department of Pediatric Dentistry, Faculty of Dentistry, Fırat University, 23119 Elazığ, Turkey. · Department of Prosthodontics, Faculty of Dentistry, Fırat University, 23119 Elazığ, Turkey.

Key points

From the paper's conclusion
  • Statistically significant differences were observed among all groups (p < 0.001), with all 3D-printed resin crown systems exhibiting lower marginal gap values than the prefabricated zirconia crowns.

Abstract

Objective: This study aimed to compare the marginal gap values of prefabricated zirconia and resin crowns fabricated using different three-dimensional (3D) printing technologies for primary molars using a 3D digital analysis method. Materials and Methods: Forty crowns (n = 10/group) were evaluated, including prefabricated zirconia crowns (NuSmile) and three resin crown systems fabricated using different additive manufacturing technologies: Crowntec (Saremco, DLP), Permanent Crown Resin (Formlabs, SLA), and Graphy TC-80DP (MSLA). All restorations were cemented with self-adhesive resin cement. The specimens were scanned before and after cementation, and the obtained STL datasets were superimposed using the Geomagic Control X software. Marginal gap values were calculated using three-dimensional (3D) digital analysis. Data were analyzed using one-way ANOVA and Games-Howell post hoc tests (α = 0.05). Results: The mean marginal gap values differed among the groups. The lowest marginal gap value was observed in the Formlabs group (113.22 ± 1.94 µm), followed by that of the Saremco group (118.54 ± 1.58 µm). Higher marginal gap values were recorded in the Graphy group (134.23 ± 2.16 µm), whereas the highest value was observed in the prefabricated zirconia crown group (163.14 ± 3.95 µm). Statistically significant differences were observed among all groups (p < 0.001), with all 3D-printed resin crown systems exhibiting lower marginal gap values than the prefabricated zirconia crowns. Conclusions: Within the limitations of this in vitro study, 3D-printed resin crowns exhibited superior marginal adaptation compared to prefabricated zirconia crowns. Among the evaluated materials, the SLA-fabricated Formlabs crowns exhibited the lowest marginal gap values. All tested resin crown systems demonstrated marginal gap values within clinically acceptable limits.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Three-Dimensional Evaluation of Marginal Gap in Prefabricated Zirconia and 3D-Printed Pediatric Crowns — Science Skim