Key points

From the paper's conclusion
  • Background: There is a need to provide a translational evaluation of imipenem-cilastatin as an innovative musculoskeletal embolic agent by assessing its embolization efficacy, physicochemical behavior, and safety profile in a porcine model of intratendinous neovascularization.

Abstract

Background: There is a need to provide a translational evaluation of imipenem-cilastatin as an innovative musculoskeletal embolic agent by assessing its embolization efficacy, physicochemical behavior, and safety profile in a porcine model of intratendinous neovascularization. Materials and Methods: In vitro analyses were performed to assess size distribution and solubility of imipenem-cilastatin in iodinated contrast media (Visipaque®) for two commercial formulations (Tienam® and Sun®). A preclinical study was conducted on six pigs, with neovascularization induced via collagenase injection in the patellar tendon. Each animal received Tienam® embolization with Visipaque® on one side and Visipaque® alone on the contralateral side at D7 post induction, followed by angiographic evaluation at D14. Efficacy was assessed using a four-point neovascularization score. Safety was evaluated through behavioral monitoring and rectal flora analysis. Results: In vitro, imipenem-cilastatin exhibited heterogeneous particle morphology and size: D50 was similar between Tienam® and Sun®, whereas D90 was markedly larger in Tienam® than Sun®, with limited solubility in Visipaque®. In vivo, Tienam® embolization led to variable reductions in neovascularization, ranging from complete to absent response (mean score decrease: 1.3 vs. 0.2 in controls, p = 0.07). Microbiological analysis revealed alterations in the rectal flora of all animals, with emergence of intrinsically carbapenem-resistant environmental species in four pigs, without evidence of acquired resistance. Conclusions: Imipenem-cilastatin demonstrates technical feasibility as a musculoskeletal embolic agent, but its efficacy remains heterogeneous, likely because of crystal irregularity and a broad size distribution. Although the procedure was clinically tolerated, the observed microbiota changes raise concerns regarding long-term safety and broader clinical adoption. Future research should focus on calibrated formulations that preserve embolic efficacy while improving reproducibility and minimizing off-target microbiological impact.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Toward More Predictable Musculoskeletal Embolization: A Translational Evaluation of Imipenem-Cilastatin Performance and Safety in a Porcine Model of Tendon Neovascularization — Science Skim