Genicular Artery Embolization Using Imipenem/Cilastatin vs. Microsphere for Knee Osteoarthritis (GAUCHO). 12-Month Clinical Results of a Single-blind Randomized Controlled Trial
Mateus P. Correa, Alexandre Fróes Michelin, Lyson Azevedo Aguiar, Ricardo Lugokenski, Rodrigo Ilha Algarve, Joaquim M. Motta-Leal-Filho
Universidade de Passo Fundo · Hospital Ortopédico de Passo Fundo
Key points
From the paper's conclusion- To compare the safety and clinical outcomes of genicular artery embolization (GAE) performed with permanent microspheres (PM) and imipenem/cilastatin (I/C) in patients with mild-to-moderate knee osteoarthritis.
Abstract
PURPOSE: To compare the safety and clinical outcomes of genicular artery embolization (GAE) performed with permanent microspheres (PM) and imipenem/cilastatin (I/C) in patients with mild-to-moderate knee osteoarthritis. MATERIALS AND METHODS: In this IRB-approved prospective, randomized, single-center, single-blind trial, 60 patients with mild-to-moderate knee osteoarthritis were allocated to GAE with I/C (n = 30) or microspheres (n = 30). Clinical outcomes were assessed at baseline, 30 days, 90 days, and 365 days using Visual Analog Scale (VAS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Knee Injury and Osteoarthritis Outcome Score (KOOS). RESULTS: Baseline characteristics were similar between groups, except for a higher rate of bilateral treatment in the microsphere group (56.6% vs. 30.0%, p = 0.037). Technical success was achieved in all procedures, with lower embolic volume in the microsphere group (p = 0.003). The mean volume of embolic was 1.5 ml in the microsphere group and 2.0 ml in the I/C group (p = 0.003). Between-group comparisons showed no significant differences in VAS at 30, 90, and 365 days (3.20 vs. 2.28, p = 0.102; 3.38 vs. 3.33, p = 0.931; and 3.95 vs. 3.88, p = 0.928), in WOMAC pain (6.25 vs. 4.83, p = 0.182; 8.11 vs. 6.00, p = 0.051; and 7.50 vs 6.27, p = 0.323), or in KOOS pain (63.59 vs. 72.12, p = 0.115; 56.58 vs. 67.14, p = 0.074; and 53.76 vs. 65.81, p = 0.081) for I/C versus microspheres, respectively. CONCLUSION: GAE using either I/C or microspheres is safe and effective, with significant clinical improvement over 12 months and no major differences in adverse events and pain outcomes between embolic agents.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Imipenem/Cilastatin Versus Imipenem/Cilastatin Plus Lipiodol in Genicular Artery Embolization: Safety and Clinical Success in a Comparative Cohort Study.Journal of vascular and interventional radiology : JVIR · 2026
- Genicular Artery Embolization Using Resorbable Gelatin Microspheres for Refractory Knee Pain: Technique, Safety and Clinical OutcomeCardioVascular and Interventional Radiology · 2025
- Genicular Artery Embolization (GAE) for the Treatment of Advanced Knee Osteoarthritis in Selected Nonoperative Patients: A Pilot Study at 6 Months Follow-Up.Journal of clinical medicine · 2026
- Genicular Artery Embolization Using Rapidly Resorbable Gelatin-based Microspheres for Osteoarthritis-related Knee PainRadiology · 2026
- Genicular artery embolisation for the management of knee osteoarthritis: a prospective randomised study.Clinical radiology · 2026
- Potential Predictors of Pain and Stiffness Response Following Genicular Artery Embolization for Knee OsteoarthritisJournal of Clinical Medicine · 2026