A Sustainable Air-Assisted Liquid-Liquid Microextraction Procedure Coupled to Liquid Chromatography-Tandem Mass Spectrometry for the Determination of 11-Nor-9-carboxy-Δ9-tetrahydrocannabinol and Hexahydrocannabinol Metabolites in Urine.
Pamela Cabarcos-Fernández, Sara Odoardi, Serena Mestria, Valeria Valentini, Giulia Biosa, Ana María Bermejo-Barrera, Sabina Strano-Rossi
Forensic Toxicology Service, Institute of Forensic Science, Faculty of Medicine, Universidad de Santiago de Compostela, C/San Francisco s/n, 15782 Santiago de Compostela, Spain. · Forensic Toxicology Laboratory, Department of Health Surveillance and Bioethics, Università Cattolica del Sacro Cuore Fondazione Policlinico Gemelli IRCCS, 00168 Rome, Italy.
Key points
From the paper's conclusion- This study aimed to develop and validate a sample preparation method based on air-assisted liquid-liquid microextraction (AALLME) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) and HHC metabolites in urine.
Abstract
Hexahydrocannabinol (HHC) is a semi-synthetic cannabinoid that has recently emerged in the European market, raising concerns regarding its detection in forensic toxicology. Reliable analytical approaches are required for the determination of HHC metabolites together with conventional cannabis biomarkers in biological samples. This study aimed to develop and validate a sample preparation method based on air-assisted liquid-liquid microextraction (AALLME) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) and HHC metabolites in urine. Urine samples underwent alkaline hydrolysis followed by AALLME using a cyclohexane/ethyl acetate mixture (9:1) prior to LC-MS/MS analysis. Experimental conditions affecting extraction performance were optimized. Method validation was performed according to international guidelines. The method achieved a limit of detection of 2.5 ng/mL and a lower limit of quantification of 5 ng/mL. Precision and accuracy fulfilled the established acceptance criteria across all concentration levels. The applicability of the method was evaluated using eleven authentic THC-COOH-positive routine casework urine samples. THC-COOH was successfully quantified, whereas no HHC metabolites were detected because no urine samples from confirmed HHC users were available. The proposed workflow provides a reduced-solvent sample preparation approach compared with conventional procedures and demonstrated adequate analytical performance for the simultaneous determination of THC-COOH and HHC metabolites in urine.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a LC-MS method for the determination of synthetic cathinones in urine samples based on switchable hydrophilicity solvent extraction.Journal of analytical toxicology · 2026
- Simultaneous Quantification of 3 Synthetic Cannabinoids and 4 of Their Metabolites in Human Urine Samples and Seized Samples by LC‐MS/MSVietnam Journal of Chemistry · 2026
- Metabolite-targeted LC-HRMS quantification of emerging indazole-based synthetic cannabinoids in urine samples from an addiction treatment cohort.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- B-412 A novel approach to detect synthetic urine simultaneously with drug confirmation by LC-MS/MSClinical Chemistry · 2026
- Development and Validation of a UPLC-MS/MS Method for the Determination of Emerging Synthetic, Semi-Synthetic and Related Cannabinoids in Human Hair.Molecules (Basel, Switzerland) · 2026
- Non-psychotropic phytocannabinoids, Δ9-THC and their metabolites by means of volumetric dried blood microsamplingJournal of Cannabis Research · 2026