Journal of analytical toxicology

Development of a LC-MS method for the determination of synthetic cathinones in urine samples based on switchable hydrophilicity solvent extraction.

Talita Cristine Zeferino, Henrique Silva Bombana, Gabriela de Paula Meirelles, Rodrigo Alves de Oliveira, André Luis Fabris, José Luis da Costa, Vilma Leyton, Mauricio Yonamine

Departamento de Análises Clínicas e Toxicológicas, Faculdade de Ciências Farmacêuticas FCF/USP, Universidade de São Paulo, São Paulo, SP, BR. · Departamento de Medicina Legal, Bioética, Medicina do Trabalho e Medicina Física e Reabilitação, Faculdade de Medicina FMUSP, Universidade de São Paulo, São Paulo, SP, BR.

Key points

From the paper's conclusion
  • Overall, the method was simple and cost-effective, demonstrating its suitability for routine determination of synthetic cathinones in urine and its potential as an environmentally friendly alternative for forensic and clinical toxicology applications.

Abstract

The continuous emergence of synthetic cathinones as new psychoactive substances (NPS) poses significant challenges for analytical toxicology, demanding efficient, reliable, and environmentally sustainable approaches for their determination in biological matrices. In this study, a homogeneous liquid-liquid microextraction method based on a switchable hydrophilicity solvent (SHS-HLLME) was developed and optimized for the determination of synthetic cathinones in urine, followed by liquid chromatography-mass spectrometry analysis. A multivariate experimental design was applied to optimize key extraction parameters, enabling efficient analyte recovery while minimizing organic solvent consumption. The optimized conditions consisted of 500 µL of urine, 400 µL of SHS:HCl mixture, and 400 µL of NaOH. The method was validated, showing satisfactory linearity (R² > 0.99), limits of detection and quantification of 10 ng/mL and 20 ng/mL, respectively, as well as acceptable recovery and precision across the evaluated concentration range. Matrix effects were low (≤10.1%), indicating negligible interference from endogenous components. Compared to conventional extraction approaches, the proposed method offers a simplified workflow with reduced solvent consumption, in line with the principles of Green Analytical Toxicology. Overall, the method was simple and cost-effective, demonstrating its suitability for routine determination of synthetic cathinones in urine and its potential as an environmentally friendly alternative for forensic and clinical toxicology applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers