Source- and Geometry-Dependent Spatial Profiles in Commercial Bioluminescence Imaging: Experimental Comparison and Geant4 Simulations.
Tim Karstens, Thorsten Frenzel, Antonina Wrzeszcz, Theresa Staufer, Florian Grüner
Institute of Experimental Physics and Center for Free-Electron Laser Science (CFEL), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany. · Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany.
Key points
From the paper's conclusion- Overall, these findings demonstrate the potential of source-specific Monte Carlo simulations to investigate spatial photon transport in commercial BLI systems and to support the design and optimization of experimental studies through systematic evaluation of source and phantom parameters, potentially reducing the need for extensive experimental test series.
Abstract
In this study, we investigated the transfer of a previously established LED-based Geant4 optical-photon simulation framework to experimental bioluminescence imaging (BLI) using two commercial imaging systems. An IVIS 200 and a SmART+ BLI/CT system were used to compare spatial intensity profiles obtained from a controlled LED source and ATP-driven bioluminescence under defined phantom conditions. Direct comparison demonstrated broader spatial profiles for BLI than for LED emission, with the magnitude of the differences varying between imaging systems. To investigate the transferability of the simulation framework, a spatially extended, isotropically emitting BLI source was implemented in Geant4, including its aqueous volume and sample container. At a phantom thickness of 2.00 mm, the simulations reproduced the general characteristics of the normalized experimental BLI profiles, although the simulated spatial profiles were consistently narrower than those measured experimentally. Separate idealized two-point-source simulations were used to investigate spatial separability under controlled phantom conditions, while additional simulations demonstrated that the source-to-boundary distance influences spatial-profile formation through changes in photon entry conditions and scattering histories. Overall, these findings demonstrate the potential of source-specific Monte Carlo simulations to investigate spatial photon transport in commercial BLI systems and to support the design and optimization of experimental studies through systematic evaluation of source and phantom parameters, potentially reducing the need for extensive experimental test series.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Denoising for high-magnification bioluminescence imaging of cells by machine learning with physics-based noise modeling of EMCCD.Biophysics and physicobiology · 2026
- Beyond In Vitro Brightness: A Matched-Probe Study of Chemiluminescence Contrast for In Vivo Peroxynitrite Imaging.Analytical chemistry · 2026
- Anatomically Programmable and Optically Tunable 3D-Bioprinted Tumor-Mimicking Phantoms for Quantitative Nanofluorophore Benchmarking.bioRxiv : the preprint server for biology · 2026
- An Open, IntegratedPlatform for Multiplexed BioluminescenceMicroscopyChemical & Biomedical Imaging · 2026
- Seeing in the Dark: Intelligent Fourier Light Field Imaging for Bioluminescence MicroscopyACS Photonics · 2026
- PyFLI: A Python Library for Simulation, Parameter Estimation, and Benchmarking in Fluorescence Lifetime ImagingarXiv · 2026