Beyond In Vitro Brightness: A Matched-Probe Study of Chemiluminescence Contrast for In Vivo Peroxynitrite Imaging.
Yue Cui, Shen-Huan Li, Xue-Qiang Wang
Department of Nuclear Medicine, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou, Zhejiang310022, China. · Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Aptamer Engineering Center of Hunan Province, Hunan University, Changsha, Hunan410082, China.
Key points
From the paper's conclusion- Here, we test how measurement context affects probe ranking using two ONOO--responsive bicyclic dioxetanes, Probe 1 and Probe 2, that share the same arylboronate trigger and closely related core architecture but emit at different wavelengths.
Abstract
Probe selection for in vivo chemiluminescence imaging commonly relies on intensity and tissue-overlay measurements performed in vitro, yet these measurements do not reproduce the activation background, probe distribution, and optical environment of a living animal. Here, we test how measurement context affects probe ranking using two ONOO--responsive bicyclic dioxetanes, Probe 1 and Probe 2, that share the same arylboronate trigger and closely related core architecture but emit at different wavelengths. In black 96-well plates after ONOO- activation, the visible-emitting Probe 2 produced approximately 350-fold greater photon output than Probe 1, and Probe 2 retained the larger signal-to-background ratio in a chicken-tissue overlay experiment. These in vitro and ex vivo measurements would both favor Probe 2. In living mice, however, the ranking by analytical contrast changed. Probe 1 afforded a subcutaneous signal-to-background ratio of 489 and produced an approximately 7-fold challenged-to-control contrast in an Escherichia coli-induced peritonitis model, compared with approximately 1.5-fold for Probe 2, the absolute signal difference narrowed to approximately 3-fold. This environment-dependent reordering shows that plate intensity and tissue overlays alone can misrank probes intended for in vivo analysis. Emission wavelength, preactivation background, tissue transmission, and model-specific signal distribution must be evaluated together.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A 1,2-Dioxetane-Based Chemiluminescent Probe for In Vivo Copper Imaging.ACS chemical biology · 2026
- A superoxide anion-specific chemiluminescent probe for detection of acute inflammation.Journal of materials chemistry. B · 2026
- Molecular Engineering of Hemicyanine Scaffold for Peroxynitrite-Activated Chemiluminescence Imaging.Small (Weinheim an der Bergstrasse, Germany) · 2026
- α,α-Dicyanoolefin-Based Chemiluminophore with Conical Intersection for High-Contrast Imaging of Peroxynitrite in Ulcerative Colitis.Analytical chemistry · 2026
- Recent advances in chemiluminescence probes for Tumor microenvironment with applications in cancer diagnosis and therapyPharmaceutical Science Advances · 2026
- Development of a Fluorescent Probe for Real-Time In Vivo Imaging of Cysteine Dynamics in a Mouse Model of Lipopolysaccharide-Induced Acute Lung Injury.Bioconjugate chemistry · 2026