Analytical chemistry

Beyond In Vitro Brightness: A Matched-Probe Study of Chemiluminescence Contrast for In Vivo Peroxynitrite Imaging.

Yue Cui, Shen-Huan Li, Xue-Qiang Wang

Department of Nuclear Medicine, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou, Zhejiang310022, China. · Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Aptamer Engineering Center of Hunan Province, Hunan University, Changsha, Hunan410082, China.

Preclinical

Key points

From the paper's conclusion
  • Here, we test how measurement context affects probe ranking using two ONOO--responsive bicyclic dioxetanes, Probe 1 and Probe 2, that share the same arylboronate trigger and closely related core architecture but emit at different wavelengths.

Abstract

Probe selection for in vivo chemiluminescence imaging commonly relies on intensity and tissue-overlay measurements performed in vitro, yet these measurements do not reproduce the activation background, probe distribution, and optical environment of a living animal. Here, we test how measurement context affects probe ranking using two ONOO--responsive bicyclic dioxetanes, Probe 1 and Probe 2, that share the same arylboronate trigger and closely related core architecture but emit at different wavelengths. In black 96-well plates after ONOO- activation, the visible-emitting Probe 2 produced approximately 350-fold greater photon output than Probe 1, and Probe 2 retained the larger signal-to-background ratio in a chicken-tissue overlay experiment. These in vitro and ex vivo measurements would both favor Probe 2. In living mice, however, the ranking by analytical contrast changed. Probe 1 afforded a subcutaneous signal-to-background ratio of 489 and produced an approximately 7-fold challenged-to-control contrast in an Escherichia coli-induced peritonitis model, compared with approximately 1.5-fold for Probe 2, the absolute signal difference narrowed to approximately 3-fold. This environment-dependent reordering shows that plate intensity and tissue overlays alone can misrank probes intended for in vivo analysis. Emission wavelength, preactivation background, tissue transmission, and model-specific signal distribution must be evaluated together.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Beyond In Vitro Brightness: A Matched-Probe Study of Chemiluminescence Contrast for In Vivo Peroxynitrite Imaging — Science Skim