Biparametric Prostate MRI: Diagnostic Performance, Estimated Additional Cost of DCE, and Gadolinium Avoidance.
Gian Carlo Parenti, Nicola Pegoraro, Aldo Carnevale, Emidio Colleluori, Marcello Pasqualini, Lorenzo Mellini, Giuseppe Falcone, Francesco Feletti
Unità Operativa di Radiologia, Ospedale S. Maria delle Croci, Ravenna, Azienda USL della Romagna, 48121 Ravenna, Italy. · Dipartimento di Medicina Traslazionale, Università di Ferrara, 44121 Ferrara, Italy.
Key points
From the paper's conclusion- In this selected biopsy cohort, biparametric MRI classified 33 of 34 clinically significant cancers as PI-RADS > 3.
Abstract
Biparametric MRI, which excludes dynamic contrast-enhanced imaging, may reduce the resources required for prostate MRI. This exploratory study assessed biparametric MRI findings against biopsy histopathology in a selected cohort and described differences from the original clinical multiparametric MRI readings. A retrospective convenience sample of 89 prostate MRI examinations with an available biparametric reassessment after removal of dynamic contrast-enhanced sequences was identified. Four patients without a classifiable histopathological diagnosis were excluded, leaving 85 patients for analysis. All had undergone biopsy following a suspicious clinical multiparametric MRI report. Two experienced radiologists each reviewed a portion of the biparametric MRI examinations while blinded to histopathology and the original multiparametric MRI report. Clinically significant prostate cancer, defined as Gleason score ≥3 + 4 (Grade Group ≥ 2), was the primary outcome. PI-RADS > 3 was considered positive. Prostate cancer was detected in 47 of 85 patients (55.3%), including 34 (40.0%) with clinically significant disease. Biparametric MRI classified 33 of 34 clinically significant cancers as PI-RADS > 3, corresponding to a sensitivity of 97.1% (95% CI, 85.1-99.5%). The corresponding sensitivity of the original clinical multiparametric MRI readings was 91.2% (95% CI, 77.0-97.0%; exploratory paired comparison, p = 0.50). Omitting dynamic contrast-enhanced imaging was estimated to reduce examination time, administered gadolinium, and the use of contrast-related materials and staff capacity under local workflow assumptions. In this selected biopsy cohort, biparametric MRI classified 33 of 34 clinically significant cancers as PI-RADS > 3. The comparison with the original multiparametric MRI readings was exploratory and cannot establish equivalence or non-inferiority. Avoiding dynamic contrast-enhanced imaging may reduce contrast administration and resource use, although the economic estimates are specific to the local workflow and environmental release was not measured.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of biparametric and multiparametric MRI for detection of clinically significant prostate cancer using PI-RADS v2.1.Current problems in diagnostic radiology · 2026
- Personalized prostate MRI protocol: Selective contrast enhancement for PI-RADS 3 lesions to optimize diagnostic accuracy and resource utilization.Acta radiologica (Stockholm, Sweden : 1987) · 2026
- The use of biparametric magnetic resonance imaging in active surveillance of prostate cancer.BJUI compass · 2026
- Baseline Whole-Gland MRI Radiomics for Risk Stratification After Suspicious mpMRI and Negative Biopsy: A MULTIPROS Sub-Analysis.Cancers · 2026
- Prostate MRI and Artificial Intelligence in Biopsy-Sparing Diagnostic Pathways: A Critical Narrative ReviewCancers · 2026
- Diagnostic performance of AI-powered prostate MRI against biopsy ground truth: quasi-continuous risk scoring versus fixed PI-RADS thresholds.Cancer imaging : the official publication of the International Cancer Imaging Society · 2026