Diagnostic performance of AI-powered prostate MRI against biopsy ground truth: quasi-continuous risk scoring versus fixed PI-RADS thresholds.
Nadine Bayerl, Joel Appel, Maximilian Schmidt, Alexander Cavallaro, Robert Grimm, Heinrich von Busch, Bernd Wullich, Arndt Hartmann,
Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg and Uniklinikum Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany. nadine.bayerl@fau.de. · Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg and Uniklinikum Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany.
Key points
From the paper's conclusion- In this retrospective single-center cohort, the AI algorithm achieved high diagnostic accuracy for csPCa. Its quasi-continuous LoS score provided an operating point combining high sensitivity with numerically higher specificity than the PI-RADS ≥ 4 threshold. Neither this difference (exact McNemar p = 0.063) nor the difference in AUC between the two classifiers (p = 0.106) reached statistical significance, so the finding should be regarded as a promising trend rather than a demonstrated advantage. Prospective confirmation is required before AI-assisted standardized interpretation is integrated into prostate MRI workflows on this basis.
Abstract
BACKGROUND: Multiparametric prostate MRI is central to prostate cancer (PCa) diagnostics, yet PI-RADS interpretation suffers from inter-reader variability. This study aimed to evaluate a commercial AI algorithm for cancer detection in prostate MRI against histopathology, comparing its standard PI-RADS classification with its quasi-continuous Level-of-Suspicion (LoS) score as decision variables. METHODS: In this retrospective single-center study, 122 mpMRI examinations, each followed by systematic and/or fusion-targeted biopsy, were analyzed. Histopathology served as the reference standard for any PCa (Gleason ≥ 6) and clinically significant PCa (csPCa; Gleason ≥ 7). Diagnostic performance of the algorithm's PI-RADS and LoS outputs was assessed by ROC analysis. AUCs were compared using DeLong's test. The Youden-optimal LoS cutoff was determined, its optimism was quantified by bootstrap internal validation, and the calibration of the LoS score was assessed after logistic recalibration. RESULTS: For csPCa, PI-RADS yielded an AUC of 0.833 (95% CI: 0.764-0.901), versus 0.882 (95% CI: 0.820-0.943) for the LoS score (p = 0.106). At PI-RADS ≥ 4, sensitivity was 94.7% and specificity 63.1%. The Youden-optimal LoS cutoff was 81. At this exploratory threshold, sensitivity remained 94.7% while specificity was 70.8%, with positive and negative predictive values of 74.0% and 93.9%, respectively. Bootstrap internal validation indicated modest optimism, with corrected estimates of 92.9% for sensitivity and 69.1% for specificity. After logistic recalibration, the bootstrap-corrected calibration slope was 0.98 with an intercept of -0.01. CONCLUSION: In this retrospective single-center cohort, the AI algorithm achieved high diagnostic accuracy for csPCa. Its quasi-continuous LoS score provided an operating point combining high sensitivity with numerically higher specificity than the PI-RADS ≥ 4 threshold. Neither this difference (exact McNemar p = 0.063) nor the difference in AUC between the two classifiers (p = 0.106) reached statistical significance, so the finding should be regarded as a promising trend rather than a demonstrated advantage. Prospective confirmation is required before AI-assisted standardized interpretation is integrated into prostate MRI workflows on this basis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multicentre evaluation of artificial intelligence risk classification for detection of clinically significant prostate cancer on biparametric MRI.European radiology · 2026
- AI-Assisted Interpretation of Prostate MRI: A Narrative Review.Journal of computer assisted tomography · 2026
- Characterization of prostate MRI focal lesions by combining human reading, artificial intelligence and prostate-specific antigen density: A multi-reader study.Diagnostic and interventional imaging · 2026
- Concurrent AI-human interaction in prostate cancer MRI interpretation: More hype than help?European Radiology Experimental · 2026
- Apparent diffusion coefficient-based single-sequence radiomics integrated with clinical variables and Prostate Imaging Reporting and Data System for predicting clinically significant prostate cancer.Translational andrology and urology · 2026
- Prostate MRI and Artificial Intelligence in Biopsy-Sparing Diagnostic Pathways: A Critical Narrative ReviewCancers · 2026