Comparative Analysis of Osseointegration Using Titanium Implants Coated with Graphene and Niobium: An Animal Model Study.
Marco Antonio Schueda, Charles Adriano Duvoisin, Diogo José Horst, Moisés Cohen
Department of Orthopedics and Traumatology, Federal University of São Paulo (UNIFESP), São Paulo 04023-900, Brazil. · Department of Health Sciences, Italian University Institute of Rosario (IUNIR), Rosario S2002QUA, Argentina.
Key points
From the paper's conclusion- The findings are exploratory and support further studies using randomized or counterbalanced allocation, clustered analysis, and independent biomechanical and histological specimens.
Abstract
BACKGROUND: Surface modification may influence tissue-implant interactions. This exploratory study compared the biomechanical, coating-integrity, and histological responses associated with uncoated titanium and carbon- or niobium-containing surface-processing conditions in a rabbit model. METHODS: Twelve adult male New Zealand White rabbits were initially enrolled and allocated to 30- and 60-day healing periods. Two animals were lost before endpoint and were not replaced; ten rabbits completed the study and were analyzed, with five animals at each period. Each rabbit received four implant-site conditions: uncoated titanium, carbon-based diamond-like carbon (Graphene-DLC), niobium deposited by chemical vapor deposition (Nb-CVD), and niobium deposited by sol-gel processing (Nb-Gel). Implant stability was assessed using reverse-torque testing after formalin fixation. Histological evaluation included hematoxylin and eosin and Picrosirius Red staining. RESULTS: At 60 days, the uncoated titanium and Graphene-DLC conditions showed the highest reported mean reverse-torque values, whereas some niobium-containing conditions showed lower reported coating-integrity scores. Ordinal histological outcomes were interpreted descriptively because the sample was small, implant sites were clustered within rabbits, and implant condition was fixed to anatomical site. CONCLUSIONS: Under this protocol, the observed differences describe combined implant-site conditions and do not provide unbiased causal evidence of coating-specific effects. The findings are exploratory and support further studies using randomized or counterbalanced allocation, clustered analysis, and independent biomechanical and histological specimens.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clarifying the Experimental Unit and the Evidence for Preserved Osseointegration in a Zirconia-Silver Coating Study.Annals of biomedical engineering · 2026
- Tooth Root-Derived Graft Promotes Complete Bone Replacement in Alveolar Ridge Preservation: Comparative Study with a Collagenic Xenograft in DogsJournal of Functional Biomaterials · 2026
- Influence of Different Surface Modifications on the Reverse Torque Values of Abutment Screws: An In Vitro Study.Journal of functional biomaterials · 2026
- Comparative Evaluation of Bovine- and Porcine-Derived Xenografts in Rabbit Calvarial and Canine Mandibular Dehiscence ModelsDentistry Journal · 2026
- Immunomodulatory Hydrogel Coating with SeNPs and Lithium Silicate Synergistically Promotes Osseointegration and Prevents Infection on Titanium ImplantsAdvanced Science · 2025
- Allograft versus xenograft for alveolar ridge preservation in non-molar extraction sockets: a systematic review and meta-analysis of randomized controlled trials.Clinical oral investigations · 2026