Multi-Organ Fat Fraction Quantification with Photon-Counting CT: Determinants, Regional Heterogeneity, and Agreement Between Spectral Fat Maps and Attenuation-Derived Fat Fraction in 270 Patients.
Flavio Spoto, Martina Roman, Giulia Vinco, Leonardo Monterubbiano, Emanuele Demozzi, Giuseppe Sala, Carmelo Cicciò, Chiara Longo,
Department of Radiology, IRCCS Sacro Cuore Don Calabria Hospital, 37024 Negrar di Valpolicella, Italy. · Radiology Unit, Department of Diagnostics and Public Health, University of Verona, G.B. Rossi Hospital, Azienda Ospedaliera Universitaria Integrata di Verona (AOUI Verona), 37134 Verona, Italy.
Key points
From the paper's conclusion- We quantified the fat fraction (FF) in the liver, spleen, pancreas, and psoas, assessed determinants and regional heterogeneity, and compared spectral FF with an attenuation-derived PDFF estimate (HU-PDFF).
Abstract
Background/Objectives: Photon-counting CT (PCCT) spectral fat maps allow fat quantification on routine scans. We quantified the fat fraction (FF) in the liver, spleen, pancreas, and psoas, assessed determinants and regional heterogeneity, and compared spectral FF with an attenuation-derived PDFF estimate (HU-PDFF). Methods: In total, 270 consecutive patients underwent abdominal PCCT. On the unenhanced acquisition, 14 ROIs per patient were placed, recording spectral FF and 70 keV attenuation; no external reference standard was available. Agreement was assessed via ICC and Bland-Altman analysis. Results: Mean FF was 4.2% (liver), 12.3% (spleen), 23.1% (pancreas), and 15.2% (psoas); 34.8% had hepatic steatosis (FF ≥ 5%). In exploratory analyses, BMI was the main independent correlate of hepatic and pancreatic FF, and psoas FF was associated with BMI, age, and male sex; splenic FF was unrelated to BMI and age. Hepatic FF showed no systematic supra-/infra-portal difference (ICC 0.97); the pancreatic tail was leaner than the body and head. Spectral FF and attenuation correlated strongly in the liver, pancreas, and psoas (r = -0.82 to -0.92), but spectral FF was 4.6 points lower than HU-PDFF in the liver and 2.7-3.4 points higher in the pancreas and psoas; liver attenuation ≤ 58.7 HU corresponded to FF ≥ 5% (AUC 0.93; cross-validated sensitivity and specificity 86%). Conclusions: PCCT fat maps are feasible for multi-organ fat measurement. Spectral FF and HU-PDFF are highly correlated but not interchangeable because of organ-specific offsets, whose source and absolute accuracy must be established against MRI-PDFF.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uniform quantification of hepatic fat fraction across body sizes using photon-counting CT.European journal of radiology · 2026
- Robust Liver Steatosis Quantification Using Photon-Counting CT in Comparison to PDFF: Validation across Protocols and Cohorts.Academic radiology · 2026
- A Prediction Model for Metabolic Abnormality Clustering Based on Abdominal Body Composition Parameters From Photon-counting CT: Development and Internal Validation.Academic radiology · 2026
- Multi-vendor, multi-field strength validation of MRI-Proton density fat fraction for fat quantification: A standardized phantom studyJournal of the Formosan Medical Association · 2026
- Quantitative assessment of vertebral bone marrow adipose tissue using photon-counting CT compared with MRI.European journal of radiology · 2026
- Dual-Energy Computed Tomography Versus Conventional Magnetic Resonance In-Phase/Opposed-Phase Imaging for Liver Fat Fraction Quantification: A Retrospective Cohort Study.Diagnostics (Basel, Switzerland) · 2026