Journal of clinical medicine

Multi-Organ Fat Fraction Quantification with Photon-Counting CT: Determinants, Regional Heterogeneity, and Agreement Between Spectral Fat Maps and Attenuation-Derived Fat Fraction in 270 Patients.

Flavio Spoto, Martina Roman, Giulia Vinco, Leonardo Monterubbiano, Emanuele Demozzi, Giuseppe Sala, Carmelo Cicciò, Chiara Longo,

Department of Radiology, IRCCS Sacro Cuore Don Calabria Hospital, 37024 Negrar di Valpolicella, Italy. · Radiology Unit, Department of Diagnostics and Public Health, University of Verona, G.B. Rossi Hospital, Azienda Ospedaliera Universitaria Integrata di Verona (AOUI Verona), 37134 Verona, Italy.

Key points

From the paper's conclusion
  • We quantified the fat fraction (FF) in the liver, spleen, pancreas, and psoas, assessed determinants and regional heterogeneity, and compared spectral FF with an attenuation-derived PDFF estimate (HU-PDFF).

Abstract

Background/Objectives: Photon-counting CT (PCCT) spectral fat maps allow fat quantification on routine scans. We quantified the fat fraction (FF) in the liver, spleen, pancreas, and psoas, assessed determinants and regional heterogeneity, and compared spectral FF with an attenuation-derived PDFF estimate (HU-PDFF). Methods: In total, 270 consecutive patients underwent abdominal PCCT. On the unenhanced acquisition, 14 ROIs per patient were placed, recording spectral FF and 70 keV attenuation; no external reference standard was available. Agreement was assessed via ICC and Bland-Altman analysis. Results: Mean FF was 4.2% (liver), 12.3% (spleen), 23.1% (pancreas), and 15.2% (psoas); 34.8% had hepatic steatosis (FF ≥ 5%). In exploratory analyses, BMI was the main independent correlate of hepatic and pancreatic FF, and psoas FF was associated with BMI, age, and male sex; splenic FF was unrelated to BMI and age. Hepatic FF showed no systematic supra-/infra-portal difference (ICC 0.97); the pancreatic tail was leaner than the body and head. Spectral FF and attenuation correlated strongly in the liver, pancreas, and psoas (r = -0.82 to -0.92), but spectral FF was 4.6 points lower than HU-PDFF in the liver and 2.7-3.4 points higher in the pancreas and psoas; liver attenuation ≤ 58.7 HU corresponded to FF ≥ 5% (AUC 0.93; cross-validated sensitivity and specificity 86%). Conclusions: PCCT fat maps are feasible for multi-organ fat measurement. Spectral FF and HU-PDFF are highly correlated but not interchangeable because of organ-specific offsets, whose source and absolute accuracy must be established against MRI-PDFF.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers