Adaptive Dynamic Subtidal Volume Ventilation (ADSV) Technology: Fluid Dynamic Principles and Physiologic Rationale for Personalized Treatment of Acute Respiratory Distress Syndrome.
Aarthi Sekaran, Adel Bougatef, Gary Nieman
SUNY Polytechnic Institute, Department of Civil and Mechanical Engineering, Utica, NY 13502, USA. · Independent Researcher, 1090 Brussels, Belgium.
Key points
From the paper's conclusion- ADSV therefore provides a fluid-dynamic framework for mechanically responsive subtidal ventilation that may help manage the changing respiratory mechanics associated with ARDS.
Abstract
Acute respiratory distress syndrome (ARDS) imposes regionally heterogeneous, time-dependent alterations in pulmonary mechanics that fundamentally limit conventional ventilation strategies. Fixed-parameter approaches targeting global pressure, volume, or timing thresholds cannot simultaneously address the competing demands of alveolar recruitment and volutrauma prevention, nor can they adapt dynamically to the wide regional variation in compliance, resistance, and expiratory time constants that characterizes the injured lung. These limitations persist across volume-controlled, pressure-controlled, high-frequency oscillatory, and time-controlled ventilation strategies. This article provides a clinically oriented narrative review of the physiologic and fluid-dynamic principles underlying Adaptive Dynamic Subtidal Ventilation (ADSV), an emerging ventilation technology that incorporates a proximal airway device-the Sliding Venturi-that passively modulates subtidal gas delivery in response to evolving respiratory system mechanics. The device utilizes the Bernoulli and Venturi effects to establish a passive pressure-flow feedback mechanism in which downstream respiratory system mechanics influence gas entrainment, delivered subtidal volume, and airway pressure. In the low-compliance (high-elastance) ARDS lung, this may limit gas entrainment and subtidal volume delivery while maintaining distending pressure. As compliance improves, entrainment may increase, permitting larger subtidal volumes at lower pressures. This self-regulating behavior operates on millisecond timescales and adapts to changes in overall respiratory system mechanics. Patient-proximal placement facilitates rapid expiratory venting, potentially reducing circuit-related expiratory resistance and dynamic hyperinflation, although these effects require experimental validation. ADSV therefore provides a fluid-dynamic framework for mechanically responsive subtidal ventilation that may help manage the changing respiratory mechanics associated with ARDS. Bench and computational studies, followed by preclinical and clinical investigations, are needed to characterize device performance, evaluate regional physiological effects, and establish safety and efficacy in ARDS.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Missing Dimension in Lung-Protective Ventilation: Physiologically Directed Inspiratory and Expiratory Time.Journal of clinical medicine · 2026
- Lung protection in acute respiratory distress syndrome: moving from protective ventilation to precision respiratory support.Current opinion in critical care · 2026
- Optimizing aerosol therapy in mechanically ventilated acute respiratory distress syndrome: a delivery-fidelity framework.Frontiers in medicine · 2026
- Lung-protective ventilation strategy in acute respiratory distress syndrome: a critical reappraisal of current practiceCritical Care · 2025
- Flow-controlled ventilation versus pressure-controlled ventilation in moderate to severe ARDS patients: a randomized crossover physiological studyIntensive Care Medicine Experimental · 2025
- Global Protective Ventilator Settings Are Not Regional Protection: A Compartment-Resolved Framework for Personalizing Mechanical Ventilation in Acute Respiratory Distress Syndrome.Journal of clinical medicine · 2026