Global Protective Ventilator Settings Are Not Regional Protection: A Compartment-Resolved Framework for Personalizing Mechanical Ventilation in Acute Respiratory Distress Syndrome.
Michael S Champagne
VentGuard Analytics, LLC, Webster, TX 77598, USA.
Key points
From the paper's conclusion- Conclusions: Within this model, global protection did not ensure regional protection.
Abstract
Background: Lung-protective ventilation in acute respiratory distress syndrome (ARDS) is guided by whole-lung measures, although the same acceptable breath may stabilize regions undergoing repeated alveolar collapse and expansion (RACE) while overdistending tissue already open. Fatigue-Aware Alveolar Stress and Strain Tracking (FAAST) is a clinician-in-the-loop framework designed to make this regional tradeoff observable. Methods: We first constructed a deterministic, twenty-compartment, phenotype-conditioned model from published observations of acute lung injury. With FAAST excluded, the test lung was evaluated controller-blind against nine prespecified correspondence targets under conventional ventilation and frozen after all nine were met. FAAST was then applied in four experiments examining alternative ventilator strategies, regional observability, a recruitment-overdistension crossover, and the interaction between recruitment and tidal-volume reduction. Results: Before FAAST analysis, the frozen phenotype model met all nine prespecified correspondence targets. FAAST analysis then showed that globally acceptable pressures could coexist with suprathreshold regional loading, while a summed-dose controller obscured opposing regional states. At 96 h, median modeled structural-compliance loss was 61.4% at positive end-expiratory pressure (PEEP) 8 cm H2O, 40.7% with the FAAST crossover at mean PEEP 13.5 cm H2O, and 39.3% at fixed PEEP 15. In a fresh virtual cohort, the crossover remained favorable to PEEP 8 in every matched case. Tidal-volume reduction lowered loss by 1.2 points at practice PEEP and 5.9 points after recruitment, with a 4.4-point interaction. No strategy eliminated regional injury. Conclusions: Within this model, global protection did not ensure regional protection. Compartmental analysis preserved information lost through aggregation and generated hypotheses for matching the complete ventilator pattern to lung state. These model-conditional findings do not establish clinical efficacy or a validated PEEP target; external waveform, imaging, physiologic, and outcome validation is required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fatigue-aware alveolar stress and strain tracking: a theoretical biomechanics framework for regional mechanical dose accumulation in ventilator-induced lung injury.Frontiers in bioengineering and biotechnology · 2026
- Lung stress mapping: an innovative technology to visualize the hidden risk of ventilator-induced lung injuryAmerican Journal of Respiratory and Critical Care Medicine · 2026
- Predicting global and regional respiratory response in ARDS patients through individualized physics-based computational lung models: a prospective clinical pilot study.Respiratory research · 2026
- Lung protection in acute respiratory distress syndrome: moving from protective ventilation to precision respiratory support.Current opinion in critical care · 2026
- Lung-protective ventilation strategy in acute respiratory distress syndrome: a critical reappraisal of current practiceCritical Care · 2025
- Global versus regional effects of PEEP on recruitment and strain: insights from preclinical and clinical studiesJournal of Applied Physiology · 2026