Serum Troponin and Procedural Duration Predict Delayed iASD Closure After Left Atrial Arrhythmia Ablation.
Ameen Abdulhasan Al-Alwany, Umniah Khajori, Mustafa Majid, Ghazi Farhan Haji, Giustino Varrassi
College of Medicine, University of Baghdad, Bab Al-Muadham, Baghdad 10047, Iraq. · Research Department, Fondazione Paolo Procacci, 00193 Roma, Italy.
Key points
From the paper's conclusion- Serum troponin concentrations, procedural duration, and echocardiographic assessment of iASD size were evaluated prospectively to determine their association with delayed atrial septal defect closure over a period of 3–6 months.
Abstract
Background: Transseptal puncture is routinely performed to access the left atrium during catheter ablation of left atrial tachyarrhythmias. Although iatrogenic atrial septal defects (iASDs) frequently occur after the procedure, factors influencing delayed defect closure remain incompletely understood. Myocardial injury induced by radiofrequency (RF) ablation results in the release of cardiac troponin into the circulation and may reflect the extent of procedural tissue injury. Methods: This prospective study included patients who underwent RF ablation for left atrial arrhythmias at the Iraqi Center for Heart Diseases in collaboration with the College of medicine, University of Baghdad between March 2023 and April 2024. Serum troponin concentrations, procedural duration, and echocardiographic assessment of iASD size were evaluated prospectively to determine their association with delayed atrial septal defect closure over a period of 3-6 months. Results: Forty-seven patients were enrolled (mean age, 36.28 ± 10.34 years; 48.9% male). A significant positive association was observed between iASD size and serum troponin level (p < 0.001). For each unit increase in post-procedure troponin, the likelihood of ASD presence increases by more than two-fold at 3-6 months. Larger septal defects were also associated with longer procedural duration. Conclusions: Elevated serum troponin concentration following RF ablation is associated with larger iatrogenic atrial septal defects and may serve as a useful predictor of delayed iASD closure during the first six months of follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Iatrogenic atrial septal defect following pulsed field ablation using left atrial ICEEuropean Heart Journal · 2026
- Persistent iatrogenic atrial septal defect after single-puncture, double transseptal access for 4D ICE-guided left atrial appendage occlusion: Incidence and clinical outcomes.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
- Subanalysis of transcatheter secundum ASD closure under local anaesthesia with transthoracic echocardiography and fluoroscopy: success, early complications and predictorsEuropean Heart Journal · 2026
- Residual impedance drop beyond ablation index is associated with atrial fibrillation recurrence after catheter ablationEuropean Heart Journal · 2026
- Physiological Tissue Response to Pulsed-Field Ablation for Atrial Fibrillation: Insights from Biomarker Kinetics.Physiological research · 2026
- Baseline circulating thrombospondin-1 is associated with recurrence after catheter ablation in paroxysmal atrial fibrillation: A retrospective cohort study.International journal of cardiology · 2026