International journal of cardiology

Baseline circulating thrombospondin-1 is associated with recurrence after catheter ablation in paroxysmal atrial fibrillation: A retrospective cohort study.

Wenkai Liao, Shuo Wang, Wei Huai, Lingjie Zhang, Xiyan Yang, Mulei Chen, Yuanfeng Gao, Xingpeng Liu

Key Laboratory of Hypertension, Department of Cardiology, Beijing Chaoyang Hospital Affiliated to Capital Medical University, Beijing, China. · Department of Emergency, Peking University Third Hospital, Beijing, China.

Observational · n=211

Key points

From the paper's conclusion
  • Elevated baseline circulating TSP-1 was associated with a higher risk of AF recurrence after first-time radiofrequency catheter ablation in patients with paroxysmal AF. These findings support further evaluation of TSP-1 as a candidate biomarker for pre-procedural risk stratification.

Abstract

INTRODUCTION: Recurrence after radiofrequency catheter ablation remains common in patients with paroxysmal atrial fibrillation (AF), and clinically accessible biomarkers for pre-procedural risk stratification are limited. Thrombospondin-1 (TSP-1) is a circulating matricellular protein implicated in inflammatory and profibrotic pathways. METHODS: We conducted a single-center retrospective cohort study of 211 patients with paroxysmal AF undergoing first-time radiofrequency catheter ablation. Baseline circulating TSP-1 was measured before ablation and analysed primarily as a continuous (log-transformed) variable, with a pre-specified 75th-percentile threshold used for exploratory subgroups. The primary endpoint was AF recurrence after a 3-month blanking period. Multivariable Cox regression, restricted cubic splines, time-dependent discrimination with bootstrap optimism correction, and propensity score matching (sensitivity analysis) were performed. RESULTS: During a median follow-up of 700 days, 61 patients (28.9%) experienced AF recurrence. Higher baseline TSP-1 was independently associated with recurrence in the full cohort (adjusted HR per 1-SD of log-TSP-1, 1.54; 95% CI 1.26-1.88; p < 0.001) and persisted after propensity score matching (HR 4.73; 95% CI 2.18-10.29). Adding TSP-1 improved time-dependent discrimination at 700 days (AUC 0.62 to 0.70; optimism-corrected 0.66; Harrell's C 0.627 to 0.705), although reclassification metrics were mixed and the incremental value was exploratory. CONCLUSION: Elevated baseline circulating TSP-1 was associated with a higher risk of AF recurrence after first-time radiofrequency catheter ablation in patients with paroxysmal AF. These findings support further evaluation of TSP-1 as a candidate biomarker for pre-procedural risk stratification.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Baseline circulating thrombospondin-1 is associated with recurrence after catheter ablation in paroxysmal atrial fibrillation: A retrospective cohort study — Science Skim