Comparison of the Technical Success of Obtura and StarClose Systems for Femoral Arterial Access-Site Closure in Neurointerventional Procedures: A Single-Center Retrospective Cohort Study.
Nurcan Kat, Tirdad Setayeshi
Department of Radiology, Bursa Yuksek Ihtisas Training and Research Hospital, University of Health Sciences, 16310 Bursa, Türkiye.
Key points
From the paper's conclusion- These findings do not demonstrate the superiority of either device.
Abstract
Background/Objectives: To compare technical hemostasis outcomes of collagen-based Obtura and nitinol clip-based StarClose vascular closure devices (VCDs) for femoral access-site closure after transfemoral neurointerventional procedures in two cohorts treated during non-overlapping periods. Methods: In this single-center retrospective cohort study, 166 of 250 consecutive patients undergoing transfemoral neurointervention (2022-2025) were included after exclusions; closure was performed via a 6F sheath with Obtura in 2025 (n = 98) or StarClose in 2022-2024 (n = 68). The primary endpoint was hemostasis with gentle pressure within 2 min of device deployment without additional procedure or prolonged manual compression. Unadjusted, adjusted, and propensity-score-matched (PSM) analyses were performed, along with a threshold-sensitivity analysis. Results: Technical success was 52.9% in the StarClose period and 70.4% in the Obtura period (OR, 2.11; 95% CI, 1.11-4.03; p = 0.033); the association was not significant after adjustment (OR, 1.99; 95% CI, 0.99-3.99; p = 0.053) or PSM (OR, 1.55; 95% CI, 0.72-3.30; p = 0.261). Additional compression time among failures was shorter in the StarClose period (5.5 vs. 10.0 min; p < 0.001). One pseudoaneurysm and one hematoma occurred per group; no major complications occurred. A ≤7-min threshold reversed the direction (OR, 0.77; 95% CI, 0.38-1.57; p = 0.592). Conclusions: The devices were used in completely different, non-overlapping periods; therefore, device effects cannot be separated from period effects. These findings do not demonstrate the superiority of either device. They are hypothesis-generating and provide a basis for designing prospective, concurrent comparative studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Plug-based versus suture-based vascular closure devices in large-bore femoral access for endovascular repair: a systematic review and meta-analysisFrontiers in Cardiovascular Medicine · 2026
- Clinical outcomes and cost analysis of plug-based versus suture-based vascular closure devices for percutaneous large bore aortic proceduresVASA · 2026
- Outcomes of ultrasound-guided and conventional Angio-Seal closure following antegrade femoral artery access: a systematic review and meta-analysis of observational studies with an exploratory indirect comparison.Diagnostic and interventional radiology (Ankara, Turkey) · 2026
- Stitch or seal? Suture-based versus bioabsorbable plug closure devices in transfemoral stroke thrombectomy: a multicenter cohort study.Journal of neurointerventional surgery · 2026
- Suture-mediated vascular closure for iatrogenic femoral artery pseudoaneurysms: a multicenter experience.Journal of vascular and interventional radiology : JVIR · 2026
- Vascular closure devices reduce access-site complications and improve procedural efficiency in adult electrophysiology: a systematic review and meta-analysis of 40,632 patientsEuropean Heart Journal · 2026