Fibula-Tibia Distance and Revision for Instability After Primary Total Knee Arthroplasty: An Exploratory Case-Control Study Addressing Rotational Confounding.
Hamza Murad, Aia Bowirrat, Muhammad Khatib, Feras Qawasmi, Dror Robinson, Loai Abdallah, Mohammad Shehadeh, Hazem Safadi,
Department of Orthopaedic Surgery, Rabin Medical Center, Hasharon Hospital, Petah Tikva 4937211, Israel. · Department of Information Systems, The Max Stern Yezreel Valley College, Emek Yezreel 1930600, Israel.
Key points
From the paper's conclusion- Conclusions: In this exploratory cohort a shorter fibula–tibia distance was associated with subsequent revision for instability, and the association persisted across the rotation sensitivity analyses performed.
Abstract
Background/Objectives: Instability without component loosening is a leading indication for revision total knee arthroplasty (TKA), yet no preoperative radiographic marker of this outcome has been validated. We examined whether preoperative fibula-tibia geometry on standing anteroposterior (AP) radiographs differs between patients subsequently revised for instability and non-revised controls, and whether any difference could be explained by radiographic rotation. Methods: In this exploratory retrospective case-control study, preoperative standing AP radiographs of 22 patients revised for instability without loosening (2014-2024) were compared with 29 primary-TKA controls frequency-matched on age, sex and comorbidity, analyzing the index (operated) knee in both groups. Three blinded orthopedic residents annotated 17 tibiofibular landmarks; 135 pairwise inter-landmark distances normalized to fibular head width were screened, and the distance with the best combined reliability-discrimination rank was carried forward with bootstrap optimism correction and nested repeated cross-validation. Four complementary rotation sensitivity analyses compared two rotation proxies between groups, adjusted the distance for them, decomposed it into vertical and horizontal components with an in silico rotation model, and assessed bilateral agreement. Results: The fibula lateral shaft-tibia lateral meta-diaphysis distance was shorter in revised patients (0.76 ± 0.16 vs. 0.93 ± 0.17 fibular-head-width units; p = 0.0006; area under the curve (AUC) 0.78 [95% CI 0.65-0.90], optimism-corrected 0.72, cross-validated 0.66; inter-rater ICC(A,1) 0.80). No statistically significant difference in either rotation proxy was detected, and the association persisted after adjustment for both proxies and side (odds ratio 4.00 per standard deviation, 95% CI 1.59-10.03). The difference resided mainly in the vertical component, which is less sensitive to simulated axial rotation under the model assumptions, and simulated rotation of 0-30° did not reproduce it. The bilateral agreement was moderate (r = 0.55), but the subsequently revised knee measured shorter than the contralateral knee. Conclusions: In this exploratory cohort a shorter fibula-tibia distance was associated with subsequent revision for instability, and the association persisted across the rotation sensitivity analyses performed. The distance is a hypothesis-generating candidate marker; it does not establish the risk of instability in unselected patients, and prospective, three-dimensional validation is required before any clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between tibiofemoral rotation and patellofemoral alignment before and after surgical realignment for lateral patellar instability.Journal of experimental orthopaedics · 2026
- Radiographic medial posterior tibial slope ≥16° predicts multiple revisions after anterior cruciate ligament reconstructionJournal of Experimental Orthopaedics · 2026
- Failed anterior cruciate ligament reconstructions have both increased posterior tibial slope and increased posterior tibial plateau offsetJournal of Experimental Orthopaedics · 2026
- Medial expected gap (mEG): a quantitative, biology-guided predictor of coronal plane correction and knee balance in robotic functionally aligned total knee arthroplasty.Journal of robotic surgery · 2026
- Correcting to Neutral in Severely Deformed Total Knee Arthroplasty Is Associated With Reduced Aseptic Loosening and Instability.The Journal of arthroplasty · 2026
- The anatomical origin of varus predicts the pattern of intraoperative gap imbalance and the correction required to balance the knee in robotic-assisted total knee arthroplasty: a retrospective cohort study.Journal of robotic surgery · 2026