Journal of clinical medicine

Dose Mapping and Accumulation for Re-Irradiation of Lung Cancers: Methodological Principles, Uncertainties, Quality Assurance, and Practical Clinical Considerations.

Mihaela Rosu-Bubulac, Hualiang Zhong, Indrin Julian Chetty

Department of Radiation Oncology, Virginia Commonwealth University, 1001 East Leigh Street Rm 3-089, Richmond, VA 23219, USA. · Department of Radiation Oncology, Medical College of Wisconsin, 8701 W Watertown Plank Rd., Milwaukee, WI 53226, USA.

Key points

From the paper's conclusion
  • Methods: This clinical-technical Perspective synthesizes consensus guidance, technical and the methodological literature, and representative clinical evidence to discuss rigid and deformable registration, dose mapping, biological normalization with EQD2/BED, uncertainty, quality assurance, and practical decision-making in lung re-irradiation.

Abstract

Background/Objectives: Thoracic re-irradiation is increasingly considered for recurrent, persistent, or new lung cancers after prior radiation therapy. The central clinical-technical challenge is relating prior and prospective doses across changes in anatomy, breathing state, fractionation, and imaging. Methods: This clinical-technical Perspective synthesizes consensus guidance, technical and the methodological literature, and representative clinical evidence to discuss rigid and deformable registration, dose mapping, biological normalization with EQD2/BED, uncertainty, quality assurance, and practical decision-making in lung re-irradiation. Results: Cumulative dose is an estimate with inherent uncertainty whose clinical value depends on the clinical question, anatomic stability, tissue correspondence, dose-transfer method, biological assumptions, and the consequence of error. Published cumulative dose constraints can provide useful orientation, but they are not universal pass/fail thresholds and should be interpreted together with their original endpoints, assumptions, and accumulation method. Conclusions: A focused, risk-adapted workflow can support more defensible use of cumulative dose in lung re-irradiation. Practical considerations in this article are intended to complement formal consensus guidance, institutional protocols, or patient-specific multidisciplinary judgment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Dose Mapping and Accumulation for Re-Irradiation of Lung Cancers: Methodological Principles, Uncertainties, Quality Assurance, and Practical Clinical Considerations — Science Skim