Quantitative assessment of deformable image registration accuracy for cumulative dose estimation in multi-site stereotactic re-irradiation.
Ahamed Badusha Mohamed Yoosuf, Mohd Zahri Abdul Aziz, Salem Alshehri, Mamdouh Alqathami
Department of Oncology, Ministry of National Guard Health Affairs, Riyadh, Kingdom of Saudi Arabia. yoosufah@mngha.med.sa. · Advanced Management of Liver Malignancies Program, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia.
Key points
From the paper's conclusion- Deformable registration improves cumulative dose estimation accuracy for multiple SABR re-irradiation.
Abstract
BACKGROUND: Re-irradiation of previously treated anatomical sites requires precise cumulative dose estimation to balance tumor control with organ-at-risk (OAR) tolerance. Conventional physical dose summation fails to account for inter-treatment anatomical deformations, potentially leading to systematic over- or underestimation of OAR doses. This study evaluates intensity-based deformable image registration (DIR) for improving dose accumulation accuracy in multiple stereotactic ablative radiotherapy (SABR) re-irradiation across different anatomical sites. METHODS: Sixty patients (226 lesions) who underwent robotic CyberKnife-based SABR re-irradiation (2-5 courses) to liver (36.7%), brain (36.7%), lung (10%), and spine (16.7%) metastases between 2016 and 2025 were analyzed. Cumulative OAR doses were calculated using both DIR-based approach and traditional physical summation. DIR registration accuracy was quantified using dice similarity coefficient (DSC), jaccard index (JI). Biologically effective dose (BED) and equivalent dose in 2 Gy fractions (EQD2) conversions were evaluated for dose assessments across heterogeneous fractionation schedules. RESULTS: DIR-based dose accumulation demonstrated significantly lower maximum doses compared with physical summation: liver maximum dose decreased from 123.8 ± 55.6 Gy to 83.2 ± 28.0 Gy (p < 0.001) and chest wall maximum dose reduced from 82.9 ± 22.4 Gy to 66.9 ± 18.6 Gy (p = 0.05). DIR yielded excellent spatial agreement for relatively rigid structures, including the heart, liver, kidneys, and brainstem (DSC > 0.90; JI > 0.84), whereas highly deformable organs such as the bowel and stomach demonstrated markedly inferior agreement (DSC < 0.50; JI < 0.35). Biological dose assessment revealed that DIR-guided workflow more accurately reflected cumulative dose patterns. CONCLUSION: Deformable registration improves cumulative dose estimation accuracy for multiple SABR re-irradiation. Integration of validated DIR with quantitative quality assurance and biological dose modeling provides a robust framework for multiple re-irradiation workflows. Future prospective studies correlating DIR-derived doses with clinical toxicity are warranted to validate the clinical impact of improved dosimetric accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cumulative dose evaluation in clinical reirradiation – Consensus guidance on technical considerations by the ESTRO reirradiation focus groupRadiotherapy and Oncology · 2025
- How to plan and deliver lung cancer reirradiation: A consensus approach from the ESTRO reirradiation and lung focus groups and ReCOG.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration AccuracyarXiv · 2026
- Dose Mapping and Accumulation for Re-Irradiation of Lung Cancers: Methodological Principles, Uncertainties, Quality Assurance, and Practical Clinical Considerations.Journal of clinical medicine · 2026
- Initial Experience with Special Medical Physics Consultations for Proton Re-Irradiation.International journal of radiation oncology, biology, physics · 2026
- Addressing Complexities in Reirradiation Through a Standardised Pathway.Journal of medical imaging and radiation oncology · 2026