Diagnostic accuracy of ultrasound in carpal tunnel syndrome: analysis of established and novel parameters
Qijiu Zou, Xiaoli Guo, Yifei Yin, Guheng Wang, Rui Jiang, Hongmei Gu, Xuejun Ni
Nantong University
Key points
From the paper's conclusion- This study evaluated the diagnostic accuracy of 3 ultrasound-based parameters-median nerve cross-sectional area (CSA), elasticity (E value), and blood flow pixel ratio (BFPR)-in grading carpal tunnel syndrome (CTS) severity.
Abstract
OBJECTIVES: This study evaluated the diagnostic accuracy of 3 ultrasound-based parameters-median nerve cross-sectional area (CSA), elasticity (E value), and blood flow pixel ratio (BFPR)-in grading carpal tunnel syndrome (CTS) severity. These parameters were assessed using high-frequency ultrasound, shear wave elastography (SWE), and superb microvascular imaging (SMI), with nerve conduction studies (NCS) as the reference standard. METHODS: A prospective study conducted between April 2024 and January 2025 included 128 patients with suspected CTS and 25 healthy controls, totalling 223 median nerves. CTS severity was categorized as mild, moderate, or severe based on NCS results. RESULTS: CSA increased from 10.05 mm2 in controls to 17.35 mm2 in severe CTS, E value rose from 42.35 kPa to 128.39 kPa, and BFPR increased from 3.99% to 19.76%. BFPR had the highest sensitivity for detecting mild CTS (cut-off 5.9%). Significant correlations (r > 0.78, P < .0001) were found among CSA, E value, and BFPR. ROC analysis showed excellent diagnostic accuracy with AUC values of 0.90-0.97 for distinguishing controls from CTS patients and 0.93-0.95 for differentiating mild from moderate-to-severe CTS. CONCLUSION: Multiparametric ultrasound, particularly BFPR via SMI, provides a reliable, non-invasive alternative to NCS for early CTS detection and severity grading, with potential for standardizing diagnostic guidelines. ADVANCEMENT IN KNOWLEDGE: This study improves ultrasound-based CTS diagnosis by integrating CSA, E value, and BFPR, offering an effective method for early detection and severity grading. BFPR, especially via SMI, demonstrates high sensitivity for mild CTS and could standardize diagnostic approaches.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasound-Based Severity Stratification in Carpal Tunnel Syndrome: Median Nerve Cross-Sectional Area for Distinguishing Severe from Moderate Disease.Diagnostics (Basel, Switzerland) · 2026
- Diagnostic accuracy of ultrasonography compared with nerve conduction studies in carpal tunnel syndromeFrontiers in Neurology · 2026
- Multilevel evaluation of the median nerve in carpal tunnel syndrome using microvascular doppler ultrasonography.Skeletal radiology · 2026
- Diagnostic Performance of Ultrasonographic Median Nerve Cross-Sectional Area for Carpal Tunnel Syndrome in Wheelchair Users With Spinal Cord Injury.American journal of physical medicine & rehabilitation · 2026
- Beyond Diagnostic Accuracy: Ultrasound as a Structural, Mechanical, and Procedural Phenotyping Tool in Carpal Tunnel Syndrome.Life (Basel, Switzerland) · 2026
- Shear Wave Elastography of the Abductor Pollicis Brevis in Carpal Tunnel Syndrome: Relationship with Quantitative Motor Unit Potential and Nerve Conduction Parameters.Journal of clinical medicine · 2026