Pressure-Waveform Guidance for Pulmonary Vein Occlusion During Cryoballoon Ablation: Procedural Efficiency and Repeat-Procedure Findings from a Large Single-Center Cohort.
Obaida Alothman, Ahmad Keelani, Georgi Borisov, Markus Frommhold, Hytham Abdelwahab, Gabriele D'Ambrosio, Karam Issa, Sultan Alshehri,
Arrhythmia Section, Division of Cardiology, Zentralklinik, 99437 Bad Berka, Germany.
Key points
From the paper's conclusion- Conclusions: Pressure-waveform guidance during CB-PVI is a feasible alternative to contrast-guided occlusion assessment and was associated with substantially lower intraprocedural fluoroscopy exposure.
Abstract
Background/Objectives: The cryoballoon (CB) has simplified pulmonary vein isolation (PVI) for treating atrial fibrillation (AF). Vein occlusion is usually assessed utilizing contrast media which entails possible risks and increases fluoroscopy exposure. Pressure-guided assessment of occlusion has emerged as a potential alternative. The objective of this study is to compare procedural characteristics and repeat-procedure findings of pressure-guided and contrast-guided assessment of vein occlusion. Methods: From July 2018 to December 2023, 1166 patients (485 [41%] female, mean age 65 ± 10 years) with AF (64% paroxysmal) undergoing CB-PVI were enrolled at a single-center, 368 (32%) underwent a contrast-guided and 798 (68%) a pressure-guided approach. Results: Procedure duration (90 ± 20 vs. 93 ± 23 min) and ablation time (1342 ± 361 vs. 1368 ± 406 s) were similar in pressure- and contrast- guided groups, and the acute success rate of PVI was high in both groups. The pressure-guided approach had shorter X-ray times (5.7 ± 3.4 vs. 9.5 ± 4.8 min, p < 0.0001) and lower X-ray doses (82 ± 78.9 vs. 586 ± 546 cGy/cm2, p < 0.0001). In 112 redo-procedures for arrhythmia recurrence after CB-PVI, durable isolation of all veins was observed more often after pressure-guided procedures (28/56 [50%] vs. 13/56 [23%]); per-vein durability was also higher (174/224 [78%] vs. 150/224 [67%], p = 0.015). Conclusions: Pressure-waveform guidance during CB-PVI is a feasible alternative to contrast-guided occlusion assessment and was associated with substantially lower intraprocedural fluoroscopy exposure. Repeat-procedure findings suggest a possible durability signal, but this observation should be considered exploratory and confirmed in prospective studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acute efficacy and mid-term clinical outcomes of expandable vs. fixed-size cryoballoon ablation for paroxysmal atrial fibrillation: a two-center randomized studyEuropean Heart Journal · 2026
- Pulmonary Vein Anatomy, Cooling Kinetics, and Recurrence After Cryoballoon Ablation for Atrial FibrillationJournal of Arrhythmia · 2026
- Pulmonary Vein Isolation with Different Single-Shot Ablation Devices in Patients with Atrial Fibrillation: A Prospective Observational Single-Center Clinical Evaluation.Medicina (Kaunas, Lithuania) · 2026
- Comparative one-year outcomes of pulmonary vein isolation and roof line ablation using cryoballoon versus pulsed-field ablation in persistent atrial fibrillation with left atrial dilatationEuropean Heart Journal · 2026
- Proof of concept - retrospective virtual reality pulmonary veins modeling evaluating eligibility for atrial fibrillation cryoballoon ablationEuropean Heart Journal · 2026
- Real-World Outcomes of Cryoballoon vs. Radiofrequency Ablation in Atrial Fibrillation: A Multicenter Propensity-Matched Analysis of Short- and Long-term EfficacyKorean Circulation Journal · 2026