Journal of clinical medicine

Routine Inflammation-Haemostasis Panel in Transvenous Lead Extraction: An Exploratory Prospective Single-Centre Cohort Study.

Jakub K Rokicki, Sylwia Wolff, Łukasz Januszkiewicz, Marcin Michalak, Katarzyna Czarzasta, Andrzej Cacko, Grzegorz Opolski, Marcin Grabowski

Department of Medical Informatics and Telemedicine, Medical University of Warsaw, 00-587 Warsaw, Poland. · National Oncology Institute of Maria Sklodowska-Curie-National Research Institute in Warsaw, 01-045 Warsaw, Poland.

Observational · n=53

Key points

From the paper's conclusion
  • We evaluated whether a routine inflammation-haemostasis panel (coagulation tests, blood counts and C-reactive protein [CRP]) and peri-procedural matrix metalloproteinase-9 (MMP-9) dynamics predict technical intra-procedural complexity.

Abstract

Background/Objectives: Vascular and bleeding complications drive procedural mortality in transvenous lead extraction (TLE), yet contemporary risk scores include no pre-procedural laboratory measure of haemostasis or inflammation. We evaluated whether a routine inflammation-haemostasis panel (coagulation tests, blood counts and C-reactive protein [CRP]) and peri-procedural matrix metalloproteinase-9 (MMP-9) dynamics predict technical intra-procedural complexity. Methods: Fifty-four procedures in 53 consecutive patients at a single tertiary centre were analysed prospectively (50% infective; 86 leads). Technical complexity (prolonged procedure or fluoroscopy time; advanced-tool use) was modelled with the number of extracted leads as a predictor rather than an outcome component, in prespecified and stepwise-selected logistic models with bootstrap optimism correction. Results: The infective indication predicted extraction extent (≥2 leads: 70% vs. 22%) but not technical complexity: the time-based endpoint was not associated with the indication (OR 0.38, p = 0.16), and only cumulative lead dwell time predicted advanced-tool use (OR 1.27 per year; optimism-corrected area under the curve [AUC] 0.72). No routine panel variable predicted any technical endpoint, and none survived multiplicity correction. MMP-9 neither changed peri-procedurally nor differed between indications. A principal-component composite did not improve on CRP alone (AUC 0.66 vs. 0.69; p = 0.67), and the full panel's apparent AUC (0.84) fell to 0.71 after optimism correction. Conclusions: No routine pre-procedural inflammation-haemostasis variable predicted technical complexity; the infective indication's apparent association reflected guideline-mandated complete system removal-extraction extent-rather than technical difficulty. These exploratory findings support dwell-time- and anatomy-anchored risk scoring, directed haemostasis-activation markers rather than routine screening, and prospective studies capturing bleeding endpoints.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers