JACC. Clinical electrophysiology

Safety and Efficacy of Transvenous Lead Extraction Using a Right-Sided Approach.

Joe Demian, Thomas Callahan, David O Martin, Arshneel Kochar, Pasquale Santangeli, Tyler Taigen, Medhat Farwati, Chadi Tabaja,

Department of Cardiovascular Medicine, Cardiac Electrophysiology Section, Cleveland Clinic, Cleveland, Ohio, USA. · Department of Cardiovascular Medicine, Cardiac Electrophysiology Section, Cleveland Clinic, Cleveland, Ohio, USA. Electronic address: younisa@ccf.org.

Key points

From the paper's conclusion
  • Right-sided TLE is associated with a lower rate of complete extraction and increased procedural risk, particularly sternotomy and major vascular injury, compared with left-sided TLE. These findings should be carefully weighed when implanting or extracting right-sided systems.

Abstract

BACKGROUND: Despite extensive experience with transvenous lead extraction (TLE) overall, outcomes for systems implanted on the right chest remain underexplored, largely because of their low incidence. OBJECTIVES: The objective was to evaluate whether system laterality influences TLE outcomes. METHODS: Using our institutional, prospectively maintained ExTRACT registry, we analyzed all consecutive patients undergoing TLE procedures at the Cleveland Clinic between 1996 and 2022. Patients were categorized by system laterality. Baseline characteristics, procedural characteristics, and complications were assessed. Multivariable logistic regression models evaluated the association between right-sided TLE and adverse events. RESULTS: Among 4,989 patients, 494 (9.9%) had right-sided and 4,495 (90.1%) had left-sided TLE. Compared with left-sided cases, right-sided cases had longer total lead dwell times (13.83 vs 9.26 years, P < 0.001) and were more likely to be extracted because of infection (47.57% vs 39.71%, P = 0.001). Fluoroscopy time was longer (15.95 vs 12.1 minutes; P < 0.001), and femoral workstation use more frequent (7.89% vs 4.05%, P < 0.001), yet complete extraction was lower (94.53% vs 96.44%, P = 0.034). Right-sided TLE had higher rates of sternotomy (2.83% vs 1.25%, P = 0.004) and superior vena cava or right atrial tear/perforation (2.49% vs 1.10%, P = 0.009). Thirty-day mortality was low and comparable (0.61% vs 0.47%, P = 0.727). Multivariable regression showed that right-sided TLE was associated with higher odds of sternotomy (OR = 1.92, 95% CI: 1.01-3.46, P = 0.037) and superior vena cava or right atrial tear/perforation (OR = 2.02, 95% CI: 1.01-3.78, P = 0.037). CONCLUSIONS: Right-sided TLE is associated with a lower rate of complete extraction and increased procedural risk, particularly sternotomy and major vascular injury, compared with left-sided TLE. These findings should be carefully weighed when implanting or extracting right-sided systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.