Long-Term Outcomes of Inverted-Bearing Reverse Shoulder Arthroplasty with Large Polyethylene Glenospheres.
William G Blakeney, David Graham, Stefan Bauer, Peter Campbell
West Coast Orthopaedic Centre, Subiaco, WA 6008, Australia. · Department of Surgery, The University of Western Australia, Perth, WA 6009, Australia.
Key points
From the paper's conclusion- This study evaluated long-term survivorship, complications, radiographic findings, and clinical outcomes of a large-glenosphere inverted-bearing rTSA design.
Abstract
Background: Inverted-bearing reverse total shoulder arthroplasty (rTSA), using a polyethylene glenosphere with a metal humeral liner, may reduce polyethylene wear, osteolysis, and scapular notching. This study evaluated long-term survivorship, complications, radiographic findings, and clinical outcomes of a large-glenosphere inverted-bearing rTSA design. Methods: A retrospective single-surgeon cohort included 394 primary rTSAs (363 patients; mean age 73.8 ± 8.5 years) performed between 2006 and 2018 using the same implant system. Clinical follow-up was available for 123 patients at a mean of 9.4 years. Outcomes included ASES, Oxford Shoulder Score (OSS), Subjective Shoulder Value (SSV), and pain VAS. Radiographs obtained at ≥8 years were assessed for scapular notching, glenoid loosening, and humeral osteolysis/stress shielding. Kaplan-Meier survival analysis was performed. Results: Thirty of the 257 rTSAs with revision follow-up (11.7%) underwent revision, most commonly for glenoid loosening or instability. Among patients with long-term radiographs, scapular notching occurred in 8.3% of all-polyethylene glenospheres and was limited to grade 1. Humeral osteolysis/stress shielding was present in 36%, although no humeral components were revised for loosening. Median final follow-up PROMs were ASES 75.8, OSS 42, SSV 78, and pain VAS 1. Conclusions: Large-glenosphere inverted-bearing rTSA demonstrated satisfactory long-term outcomes, low notching rates, and acceptable survivorship. The favourable notching profile should be interpreted in the context of the larger eccentric glenosphere design, which precludes attribution of this finding to bearing material alone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Polyethylene glenospheres in reverse total shoulder arthroplasty have greater long-term implant survivorship than metallic glenospheres: A New Zealand Joint Registry Study.Journal of shoulder and elbow surgery · 2026
- [Translated article] Clinical and radiological outcomes when using standard versus retentive polyethylene humeral cups in Delta III reverse shoulder arthroplasty.Revista espanola de cirugia ortopedica y traumatologia · 2026
- Comparing Inferiorized and Lateralized Glenospheres in Reverse Total Shoulder Arthroplasty Using the LimaCorporate SMR Reverse Shoulder System: A Single-Center Analysis.Journal of shoulder and elbow surgery · 2026
- Clinical and radiographic outcomes of reverse shoulder arthroplasty performed with 40 mm polyethylene glenospheres vs. 36 mm cobalt chrome glenospheres at minimum 2-years follow-up.Shoulder & elbow · 2026
- Anatomic Total Shoulder Arthroplasty: Long-Term Clinical, Radiographic, and Patient-Reported OutcomesJournal of the American Academy of Orthopaedic Surgeons · 2026
- Reverse Total Shoulder Arthroplasty in the Setting of an Intact Rotator Cuff: A Contemporary Review of Current Indications, Outcomes, and Surgical Considerations.Current reviews in musculoskeletal medicine · 2026