Polyethylene glenospheres in reverse total shoulder arthroplasty have greater long-term implant survivorship than metallic glenospheres: A New Zealand Joint Registry Study.
Stephen Bayley, Alex B Boyle, Chris Frampton, Peter Poon, Adam Dalgleish, Ryan Gao
Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand. Electronic address: stephen.s.bayley@gmail.com. · Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand.
Key points
From the paper's conclusion- In this large national registry study, IB-rTSA using a polyethylene glenosphere was associated with significantly lower revision rates than conventional metal glenosphere designs, with no statistically or clinically significant differences in patient-reported functional outcomes. In secondary, unadjusted cause-specific analyses, polyethylene glenospheres were also associated with lower rates of revision for deep infection and dislocation. Although it could not be examined using registry data, this lower revision burden may relate to the absence of polyethylene-induced osteolysis and consequently less pronounced scapular notching.
Abstract
BACKGROUND: Reverse total shoulder arthroplasty (rTSA) is increasingly common and clinically effective. Conventional-bearing rTSA (CB-rTSA) employs a metallic glenosphere articulating with a polyethylene humeral liner. Inverted-bearing rTSA (IB-rTSA), using a polyethylene glenosphere with a metallic or ceramic humeral liner, was developed to eliminate polyethylene wear debris at the scapular neck and thereby reduce polyethylene-induced osteolysis and the severity of scapular notching. Comparative data on survivorship and patient-reported outcomes between these configurations remain limited. This study compared implant survival, revision risk and functional outcomes between CB-rTSA and IB-rTSA designs. METHODS: This retrospective comparative cohort study identified all primary rTSA procedures performed in New Zealand between January 2007 and December 2024 from the New Zealand Joint Registry. Revision-free implant survival and postoperative function, measured by the Oxford Shoulder Score (OSS), were analysed. Patients were grouped by bearing configuration: polyethylene glenosphere (IB-rTSA) and metal glenosphere (CB-rTSA). Subgroup analyses compared SMR Reverse Polyethylene and SMR Reverse Metal (LimaCorporate, Italy) with other CB-rTSA designs, predominantly Delta Xtend (DePuy Synthes, USA). Revision rates per 100 component-years were calculated, and multivariable Cox proportional hazards models compared revision risk, adjusting for age, sex and diagnosis. RESULTS: A total of 8,601 rTSA procedures were included: 3,437 (40.0%) using a polyethylene glenosphere and 5,164 (60.0%) a metallic glenosphere. Indications for surgery were comparable between groups, whereas the sex distribution differed significantly. Unadjusted revision rates per 100 component-years were higher for the metal group (0.71) than the polyethylene group (0.46) (P = .001). The adjusted hazard ratio for polyethylene compared with metal was 0.57 (95% CI 0.43 - 0.75), representing a 43% lower revision rate. In secondary, unadjusted cause-specific analyses, polyethylene glenospheres were associated with fewer revisions for deep infection (0.11 vs 0.20 per 100 component-years; P = .031) and dislocation (0.09 vs 0.16; P = .045). Mean OSS at 6 months, 5 years and 10 years were similar between groups, with no statistically or clinically significant differences. CONCLUSION: In this large national registry study, IB-rTSA using a polyethylene glenosphere was associated with significantly lower revision rates than conventional metal glenosphere designs, with no statistically or clinically significant differences in patient-reported functional outcomes. In secondary, unadjusted cause-specific analyses, polyethylene glenospheres were also associated with lower rates of revision for deep infection and dislocation. Although it could not be examined using registry data, this lower revision burden may relate to the absence of polyethylene-induced osteolysis and consequently less pronounced scapular notching.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-Term Outcomes of Inverted-Bearing Reverse Shoulder Arthroplasty with Large Polyethylene Glenospheres.Journal of clinical medicine · 2026
- Clinical and radiographic outcomes of reverse shoulder arthroplasty performed with 40 mm polyethylene glenospheres vs. 36 mm cobalt chrome glenospheres at minimum 2-years follow-up.Shoulder & elbow · 2026
- Comparing Inferiorized and Lateralized Glenospheres in Reverse Total Shoulder Arthroplasty Using the LimaCorporate SMR Reverse Shoulder System: A Single-Center Analysis.Journal of shoulder and elbow surgery · 2026
- Revision risk of cross-linked versus non-crosslinked polyethylene in reverse shoulder arthroplasty: an analysis of 63,502 cases from the Australian Orthopaedic Association National Joint Replacement Registry.Journal of shoulder and elbow surgery · 2026
- Reverse Total Shoulder Arthroplasty in the Setting of an Intact Rotator Cuff: A Contemporary Review of Current Indications, Outcomes, and Surgical Considerations.Current reviews in musculoskeletal medicine · 2026
- [Translated article] Clinical and radiological outcomes when using standard versus retentive polyethylene humeral cups in Delta III reverse shoulder arthroplasty.Revista espanola de cirugia ortopedica y traumatologia · 2026