Clinical and Computational Analysis of Left Subclavian Artery Coverage on High-Risk Blunt Thoracic Aortic Injury.
Alireza Jabbarinick, Mohammadebrahim Varan, Hamidreza Pouraliakbar, Nima Rahmati, Rezvan Dadras, Jamal Moosavi, Bahram Mohebbi, Sepehr Jamalkhani,
Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran 19991-43344, Iran. · Department of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 14174-66191, Iran.
Key points
From the paper's conclusion- Results: Post-intervention, flow distribution improved significantly; relative perfusion to the brachiocephalic trunk and left common carotid artery increased by 3.51% and 4.02%, respectively, alongside an elevated overall pressure throughout the entire computational domain.
Abstract
Background/Objectives: Blunt thoracic aortic injury (BTAI) is a rare, highly lethal trauma typically occurring at the aortic isthmus. Advanced BTAI is primarily treated with thoracic endovascular aortic repair (TEVAR). Because emergent surgical debranching is rarely feasible, management depends heavily on patient anatomy, especially regarding the left subclavian artery (LSA). Patient-specific computational fluid dynamics (CFD) models offer critical insights into periprocedural planning and outcome prediction. Methods: This study investigates hemodynamic changes in a patient-specific BTAI case following intentional LSA coverage by a stent graft. Three-dimensional patient-specific models were coupled with RCR-Windkessel boundary conditions for both pre- and post-procedural imaging data to simulate blood flow in each scenario. Results: Post-intervention, flow distribution improved significantly; relative perfusion to the brachiocephalic trunk and left common carotid artery increased by 3.51% and 4.02%, respectively, alongside an elevated overall pressure throughout the entire computational domain. However, regions with high oscillatory, low magnitude shear (HOLMES), specifically wall areas with values < 0.3 Pa, expanded post-stenting. This warrants careful monitoring during follow-ups, given the associated risk of thrombus formation. Furthermore, time-averaged swirling strength (TASS) variation along the aorta decreased (standard deviation dropped from 1.8610 to 1.3835), indicating stabilized flow within the stented region, while normalized swirling strength increased distally. Conclusions: This study establishes an effective, non-invasive framework for assessing pre- and post-TEVAR hemodynamics. It demonstrates that LSA coverage induces uniformly elevated pressure and alters wall shear stress and helicity indices, highlighting the need for future research into pharmacological management to optimize long-term outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Left Subclavian Artery Management Strategies During TEVAR for Blunt Thoracic Aortic Injury: Do Branched Endografts Offer a Clinical Advantage?Journal of vascular surgery · 2026
- Computational Modeling of Thoracic Aortic Stent-Grafts: Bibliometric Analysis and Current TrendsComputation · 2026
- Clinical outcomes of external fenestration TEVAR in Stanford type B aortic dissection involving the left subclavian artery: a retrospective study.Frontiers in cardiovascular medicine · 2026
- Thoracic Branched Endografts in Acute Aortic Syndromes: Expanding Indications, but at What Cost?Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
- Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic DissectionmedRxiv · 2026
- Comparison of Numerical Models to Compute Biomechanical Markers in Ascending Thoracic Aortic Aneurysms.IEEE journal of biomedical and health informatics · 2026