Clinical outcomes of external fenestration TEVAR in Stanford type B aortic dissection involving the left subclavian artery: a retrospective study.
Chunshui Liang, Hong Liu, Xiaobo Peng, Tianbo Li, Chencheng Liu, Yong Wang, Yingbin Xiao, Ruiyan Ma
Department of Cardiovascular Surgery, Xinqiao Hospital, The Army Medical University, Chongqing, China.
Key points
From the paper's conclusion- External fenestration TEVAR demonstrates favorable clinical outcomes and hemodynamic stability in TBAD involving the LSA, effectively promoting false lumen thrombosis and aortic remodeling while preserving LSA perfusion. Our findings suggest that complete entry coverage with an adequate proximal landing zone (≥15 mm when anatomically feasible) may be important for achieving false lumen depressurization, although this observation requires further validation. Further prospective studies are warranted to validate these findings.
Abstract
OBJECTIVE: This study assessed the clinical efficacy and hemodynamic effects of external fenestration thoracic endovascular aortic repair (TEVAR) in patients with type B aortic dissection (TBAD) involving the left subclavian artery (LSA). METHODS: A retrospective analysis of 110 patients who underwent this procedure between 2020 and 2024 was conducted, evaluating procedural success, complications, and follow-up outcomes. Hemodynamic changes were analyzed in 1 patient using computational fluid dynamics (CFD) based on pre- and postoperative CT angiography (CTA). RESULTS: Technical success was achieved in all cases. Complications included 3 cases of type I endoleak (2.7%), 1 type II endoleak (0.9%), 3 type IV endoleak (2.7%), 1 LSA stenosis (0.9%), and 2 deaths (1.8%). At a 5.7-month follow-up, 92.7% of patients showed complete false lumen thrombosis. There were occurrences of type I endoleak (2.7%), type II endoleak (1.8%), type IV endoleak (2.7%), LSA occlusion (2.7%), and LSA stenosis (2.7%). CFD analysis in the representative case demonstrated restoration of physiological flow patterns, including normalized streamlines in the LSA and stabilized wall shear stress in the stented segment. CONCLUSION: External fenestration TEVAR demonstrates favorable clinical outcomes and hemodynamic stability in TBAD involving the LSA, effectively promoting false lumen thrombosis and aortic remodeling while preserving LSA perfusion. Our findings suggest that complete entry coverage with an adequate proximal landing zone (≥15 mm when anatomically feasible) may be important for achieving false lumen depressurization, although this observation requires further validation. Further prospective studies are warranted to validate these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Minimally invasive management of Stanford B aortic dissection involving the left subclavian artery.Frontiers in cardiovascular medicine · 2026
- Debranching versus Fenestrated Repair for Left Subclavian Artery Revascularisation during Thoracic Endovascular Aortic Repair: The DEFENCE Multicentre StudyEuropean Journal of Vascular and Endovascular Surgery · 2025
- Patient-specific computational simulation for thoracic endovascular aortic repair in patients with Stanford type B aortic dissection.Frontiers in cardiovascular medicine · 2026
- Clinical and Computational Analysis of Left Subclavian Artery Coverage on High-Risk Blunt Thoracic Aortic Injury.Journal of clinical medicine · 2026
- Predicting Post-TEVAR Endoleaks: A Pre-operative Hemodynamic Risk Factor from Patient-Specific Fluid-Structure Interaction Simulations.Annals of biomedical engineering · 2026
- Transcatheter Electrosurgical Aortic Septotomy Across the Spectrum of Type B Aortic Dissection: Feasibility, Technical Lessons, and Bailout Strategies.EJVES vascular forum · 2026