Reliable but Not Interchangeable: What Validated Instruments Measure When They Grade an Anastomosis.
Teona Z Carciumaru, Victor Esanu, Clemens M F Dirven, Dalibor Vasilic, Victor Volovici
Department of Plastic and Reconstructive Surgery, Erasmus MC University Medical Center, 3015 GD Rotterdam, The Netherlands. · Center for Complex Microvascular Surgery, Erasmus MC University Medical Center, 3015 GD Rotterdam, The Netherlands.
Key points
From the paper's conclusion- This study compared the behaviour of three validated instruments, ALI, MARS10, and SMaRT, when applied to identical performances.
Abstract
Background/Objectives: Multiple validated microsurgical assessment instruments exist that differ in design and theoretical approach. Product-based tools evaluate the quality of the completed anastomosis, while process-based tools assess technique during task execution. Whether these tools measure the same underlying construct and can be used interchangeably has not been directly examined. This study compared the behaviour of three validated instruments, ALI, MARS10, and SMaRT, when applied to identical performances. Methods: Forty-five participants from 26 institutions across 14 countries performed an eight-stitch end-to-end vascular anastomosis on a chicken leg model, independently evaluated by two trained graders using all three instruments. Interrater reliability was assessed using intraclass correlation coefficients (ICC(2,1)), rank-order agreement using Spearman's rho and Kendall's W, and score distributions were examined for floor and ceiling effects. Results: All three instruments demonstrated high interrater reliability (ICC: ALI 0.955, MARS10 0.939, SMaRT 0.960), though product-based tools showed wider confidence intervals. Systematic rater differences were observed across all instruments. Rank correlations were strongest between ALI and MARS10 (ρ = 0.913), with moderate correlations between process-based and product-based tools (ρ = 0.698-0.749). MARS10 showed a ceiling effect, SMaRT underutilised its upper range, and ALI had the greatest score variability. Conclusions: Although demonstrating high interrater reliability, the instruments differ in rater variability, discriminatory capacity, and the aspects of performance prioritised, embodying different definitions of surgical skill. Current tools are not interchangeable, and instrument selection carries potential consequences for training and research. Future research in technology-driven approaches could offer a path toward more objective and consistent evaluation that is less dependent on human interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multimodal Large Language Models Rate Wetlab Suturing Repeatably but Fail to Detect Training-Related Improvement: A Pilot Study With Expert Assessment.Cureus · 2026
- A Task-Specific Performance Rating Scale for Laparoscopic Intracorporeal Suturing and Knot Tying: Development and Initial Evaluation.Journal of laparoendoscopic & advanced surgical techniques. Part A · 2026
- Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study.Journal of clinical medicine · 2026
- SAFER: a simulation-based assessment tool for emergency robotic undocking with multisource validity evidence.Surgical endoscopy · 2026
- Surgeons' Perception Questionnaire on Robotics (SPQR): development and preliminary validation of a surgeon-reported instrument for robotic surgery.Journal of robotic surgery · 2026
- MicroRAG : Development of a Novel Artificial Intelligence Retrieval‐Augmented Generation Model for Microsurgery Clinical Decision SupportMicrosurgery · 2025