Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study.
Marta Aleksandra Kwiatkowska, Dominika Dobrowolska, Łukasz Skrzypiec, Dariusz Jurkiewicz
Department of Otolaryngology and Oncological Laryngology with Division of Cranio-Maxillo-Facial Surgery, Military Institute of Medicine-National Research Institute, 04-142 Warsaw, Poland.
Key points
From the paper's conclusion- We compared surgeon-perceived workload, fatigue and workflow during microscopic, conventional endoscopic and RobOtol®-assisted endoscopic ear surgery.
Abstract
Background: Otologic surgery imposes prolonged static postures and fine-motor demands on the surgeon, yet the ergonomic effect of robotic endoscope holding is unknown. We compared surgeon-perceived workload, fatigue and workflow during microscopic, conventional endoscopic and RobOtol®-assisted endoscopic ear surgery. Methods: In this prospective single-center pilot study, one surgeon performed 29 procedures: RobOtol® (n = 9), conventional endoscopy (n = 10) and microscopy (n = 10). After each procedure, the surgeon rated five NASA Task Load Index (NASA-TLX)-derived workload domains (0-10; unweighted mean), comfort, neck, eye and hand fatigue, instrument stability and movement precision. Setup time, operative time and repositionings were recorded. Kruskal-Wallis and Holm-adjusted Mann-Whitney U tests were used, with false discovery rate control across secondary outcomes. Rapid Upper Limb Assessment (RULA) scores from intraoperative photographs were analyzed descriptively. Results: Modified NASA-TLX scores were 3.58 ± 1.50 (RobOtol®), 3.78 ± 1.54 (endoscopy) and 5.52 ± 1.54 (microscopy) (p = 0.026, ε2 = 0.26); no pairwise difference remained significant after Holm adjustment. Eye fatigue was higher with microscopy than with either endoscopic approach (adjusted p ≤ 0.016). Compared with conventional endoscopy, RobOtol® yielded higher surgeon-rated instrument stability (mean difference 2.72, 95% CI 1.79-3.65; adjusted p < 0.001) and movement precision (1.04, 95% CI 0.41-1.67; adjusted p = 0.019) without higher workload. Operative time was longest with microscopy (130.7 vs 76.8 and 77.3 min; p = 0.004). Mean RULA scores were 3.38-3.77 (action level 2) in all groups. Conclusions: Endoscopic approaches were associated with lower perceived workload and eye fatigue than microscopy, and robotic endoscope holding was associated with higher perceived stability and precision without added workload. As case mix differed between groups and outcomes were self-rated, these hypothesis-generating findings require confirmation in larger multi-surgeon studies with objective performance and posture measurement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Ergonomics of Endoscopic Ear Surgery: An International Survey.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Quantifying Soft‐Surgery in Cochlear Implantation: Multimodal Data From 30 International SpecialistsThe Laryngoscope · 2026
- Surgical team ergonomics during robotic versus conventional laparoscopic surgery: a prospective observational study.Journal of robotic surgery · 2026
- Ergonomics and musculoskeletal disorders in urological surgery: Field study and prevention strategies.The French journal of urology · 2026
- A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input DevicearXiv · 2026
- Exoscope-Associated Upper-Limb Rather than Neck Postural Changes During Frontal Sinus Procedures in Bifrontal Craniotomies.Brain sciences · 2026